A micromachined piezoelectric cantilever transducer, which works both as a microphone and as a microspeaker, has been fabricated and tested, The 2000 x 2000 x 4.5 mu m(3) cantilever has a zinc oxide (ZnO) piezoelectric thin film on a supporting layer of low-pressure chemical-vapor-deposited (LPCVD) low-stress silicon nitride, A highlight of the fabrication process, which may also be relevant for other micromachined structures, is the technique for producing a Bat, multilayer cantilever. The measured microphone sensitivity is fairly constant at 3 mV/mu bar in the low frequency range and rises to 20 mV/mu bar at the lowest resonant frequency of 890 Hz. The 3 mV/mu bar sensitivity is the highest reported to date for a microphone with a micromachined diaphragm. When measured into a 2 cm(3) coupler with 4 V(zero-peak) drive, the microspeaker output sound pressure level (SPL) is 75 dB at 890 Hz. It increases to approximately 100 dB SPL at 4.8 kHz with 6 V(zero-peak) drive. The measured microphone frequency response agrees well with the results of an ABAQUS simulation.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
1996
Language
English
Article Type
Article
Keywords

CONDENSER MICROPHONE; SILICON

Citation

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, v.5, no.4, pp.238 - 242

ISSN
1057-7157
URI
http://hdl.handle.net/10203/73817
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 101 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0