The existence of the early-negative blood-oxygenation-level-dependent (BOLD) response is controversial and its practical utility for mapping brain functions with columnar spatial specificity remains questionable. To address these issues, gradient-echo BOLD fMRI studies were performed at 4.7 T and 9.4 T using the well-established orientation column model in the cat visual cortex. A robust transient early-negative BOLD response was consistently observed in anesthetized cat (-0.35 +/- 0.09%, mean +/- SD, n = 8 at 2.9 +/- 0.5 sec poststimulus onset for 4.7 T, TE = 31 ms; -0.29 +/- 0.10%, n = 4 at 3.0 +/- 0.8 sec poststimulus onset for 9.4 T, TE = 12 ms). In addition to its temporal evolution, the BOLD response also evolved dynamically in the spatial domain. The initially spatially localized early-negative signal appeared to dynamically drain from the active sites toward large vessels, followed by a wave of the delayed positive signal, which exhibited similar spatiotemporal dynamics. Only the early-negative BOLD response within 2 sec of the stimulus onset (not the entire dip) yielded columnar layouts without differential subtraction. The functional maps of two orthogonal orientations using the first 2-sec dip were indeed complementary. On the other hand, the delayed positive BOLD response appeared diffused and extended beyond the active sites. It was thus less suitable to resolve columnar layouts. These results have implications for the design and interpretation of the BOLD fMRI at columnar resolution. Magn Reson Med 44:231-242, 2000. (C) 2000 Wiley-Liss, Inc.
Publisher
JOHN WILEY SONS INC
Issue Date
2000-08
Language
English
Article Type
Article
Keywords

HIGH MAGNETIC-FIELDS; CAT VISUAL-CORTEX; SENSORY STIMULATION; FUNCTIONAL MRI; HUMAN BRAIN; OCULAR DOMINANCE; STRIATE CORTEX; BLOOD-FLOW; IN-VIVO; ACTIVATION

Citation

MAGNETIC RESONANCE IN MEDICINE, v.44, no.2, pp.231 - 242

ISSN
0740-3194
DOI
10.1002/1522-2594(200008)44:2<231::AID-MRM10>3.3.CO;2-K
URI
http://hdl.handle.net/10203/73639
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 144 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0