Wide Range-Sensitive, Bending-Insensitive Pressure Detection and Application to Wearable Healthcare Device

Cited 3 time in webofscience Cited 0 time in scopus
  • Hit : 57
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, Seunghwanko
dc.contributor.authorAmjadi, Mortezako
dc.contributor.authorLee, Tae-Ikko
dc.contributor.authorJeong, Yongrokko
dc.contributor.authorKwon, Dongukko
dc.contributor.authorKim, Min Seongko
dc.contributor.authorKim, Kyuyoungko
dc.contributor.authorKim, Taek-Sooko
dc.contributor.authorOh, Yong Sukko
dc.contributor.authorPark, Inkyuko
dc.date.accessioned2023-07-20T02:01:57Z-
dc.date.available2023-07-20T02:01:57Z-
dc.date.created2023-07-07-
dc.date.created2023-07-07-
dc.date.issued2019-06-
dc.identifier.citation20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, TRANSDUCERS 2019 and EUROSENSORS XXXIII, pp.374 - 377-
dc.identifier.urihttp://hdl.handle.net/10203/310700-
dc.description.abstractThis paper reports a wide range-sensitive, bending-insensitive pressure sensor based on a carbon nanotube (CNT)-coated porous elastomer for a wearable healthcare application. (1) Sensing performance was evaluated over ∼1MPa, which includes whole human tactile and body weight levels. The sensor exhibits a very wide sensing range from ultralow to high pressure (50Pa-1MPa) with maintenance of favorable sensitivity and reliable dynamic responses. (2) To our knowledge this is the first to investigate bending-insensitivity of the CNTs-coated porous PDMS, which facilitates accurate detection of normal pressures even on curved surfaces like human skins. (3) Finally, we demonstrated a foot insole for real-time monitoring of foot plantar pressure distribution.-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleWide Range-Sensitive, Bending-Insensitive Pressure Detection and Application to Wearable Healthcare Device-
dc.typeConference-
dc.identifier.wosid000539487000095-
dc.identifier.scopusid2-s2.0-85071906602-
dc.type.rimsCONF-
dc.citation.beginningpage374-
dc.citation.endingpage377-
dc.citation.publicationname20th International Conference on Solid-State Sensors, Actuators and Microsystems and Eurosensors XXXIII, TRANSDUCERS 2019 and EUROSENSORS XXXIII-
dc.identifier.conferencecountryGE-
dc.identifier.conferencelocationBerlin-
dc.identifier.doi10.1109/TRANSDUCERS.2019.8808529-
dc.contributor.localauthorKim, Taek-Soo-
dc.contributor.localauthorPark, Inkyu-
dc.contributor.nonIdAuthorKim, Seunghwan-
dc.contributor.nonIdAuthorAmjadi, Morteza-
Appears in Collection
ME-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 3 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0