MR 감쇠기가 설치된 지진격리 건물의 스마트 진동제어Application of Some Semiactive Control Algorithms to a Smart Base Isolated Building Employing MR Dampers

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 493
  • Download : 0
초록 This paper investigates the effectiveness of the MR damper-based control systems for seismic protection of base isolated building sturcutres employing some semiactive control algorithms, such as the modified clipped-optimal control, the maximum energy dissipation, and the modulated homogeneous friction, by examining the Phase I smart base isolated benchmark building problem. The results of the numerical simulations showed that most of the control systems considered herein could be beneficial in reducing seismic responses, especially base displacement or isolator deformation, of base isolated building structures. It is also verified that another version of the modified clipped-optimal control algorithm proposed in this study and the modulated homogeneous friction algorithm are more effective than other semiactive control algorithms.
Publisher
한국지진공학회
Issue Date
2005-03
Language
KOR
Citation

2005년도 한국지진공학회 학술발표회, pp.544 - 551

URI
http://hdl.handle.net/10203/153200
Appears in Collection
CE-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.