다중 CCD를 이용한 부피간섭계의 성능개선The performance improvement of the volumetric interferometer with multi-CCDs

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 279
  • Download : 0
The Volumetric Interferometer using two spherical wavefronts emitted from the ends of two single mode fibers has been suggested to measure 3-dimensional absolute coordinates. In this paper, we try to improve the performance of the volumetric interferometer using multi-CCDs. We get coordinates matching matrixes between CCDs and can obtain more information in the space with multi-CCDs. Also we find out the best arrangement of multi-CCDs by computer simulations. In the simulation we can know that it will be better to increase the distance between CCDs to improve performance. For the performance test, we do a repeatability test, a comparison test with 2-D stage and the self-calibration using artifact.
Publisher
한국정밀공학회
Issue Date
2003-06
Language
KOR
Citation

한국정밀공학회 춘계학술발표회, pp.268 - 271

URI
http://hdl.handle.net/10203/152379
Appears in Collection
ME-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.