매스콘크리트 구조물에서 파이프 쿨링을 고려한 수화열 해석Thermal Analysis Associated with the Application of Pipte Cooling System to a massive Concrete Structure

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 624
  • Download : 0
Pipe cooling has been popularly used in the mass concreting work to reduce temperature of the structure since it is known to be the easiest way to apply and has been the customary usage. But wrong application of the system results in the harmful effect on the structure by crack formation due to thermal shocks and improper cooling schemes. Thus, this study aims at the suppling of effective cooling methods through parametric study. For this, circulating method, velocity of water supply and circulating duration were selected as critical factors affecting the effectiveness of cooling system. As a results of thermal analysis, it was found that too much thermal gradient in the vicinity of the pipe creates localized radial or circumferential cracks. The duration of circulating cooling may be recommended to be as short as several days which may safely reduce the concrete temperature to below a final stable value. It was also found that pipe cooling is more effective to decrease the degree external restraints than internal one.
Publisher
한국콘크리트학회
Issue Date
1998-10
Language
KOR
Citation

1998 한국콘크리트학회 가을 학술대회, pp.922 - 927

URI
http://hdl.handle.net/10203/125065
Appears in Collection
CE-Conference Papers(학술회의논문)