DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shin, Goo-Hwan | ko |
dc.contributor.author | Ryu, Kwang-Sun | ko |
dc.contributor.author | Myung, Noh-Hoon | ko |
dc.contributor.author | Kim, Ee-Eul | ko |
dc.date.accessioned | 2013-03-11T16:20:45Z | - |
dc.date.available | 2013-03-11T16:20:45Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2011-08 | - |
dc.identifier.citation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.59, pp.670 - 673 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | http://hdl.handle.net/10203/99584 | - |
dc.description.abstract | The ICS307GI-03LF is a dynamic, serially programmable clock source that is flexible and takes up minimal board space and whose output frequencies are programmed via a serial interface port. The device can be programmed during operation, making it ideal for applications where many different frequencies are required. To apply it to space parts, we have performed a total ionizing dose (TID) test for the ICS307GI-03LF serially programmable clock source by using a low-level gamma irradiator with (60)Co gamma-ray sources at the ARTI (Advanced Radiation Technology Institute), which belongs to the KAERI (Korea Atomic Energy Research Institute). The irradiation with gamma-rays was carried out at doses from 0 krad to 100 krad to check the status of the device in terms of frequency and current. In this paper, we report on the TID test results for the ICS307GI-03LF clock source. | - |
dc.language | English | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.subject | MEMORY | - |
dc.title | TID Effect Test of the ICS307GI-03LF Serially Programmable Clock Source for Space Applications | - |
dc.type | Article | - |
dc.identifier.wosid | 000294079700032 | - |
dc.identifier.scopusid | 2-s2.0-79961232428 | - |
dc.type.rims | ART | - |
dc.citation.volume | 59 | - |
dc.citation.beginningpage | 670 | - |
dc.citation.endingpage | 673 | - |
dc.citation.publicationname | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.embargo.liftdate | 9999-12-31 | - |
dc.embargo.terms | 9999-12-31 | - |
dc.contributor.localauthor | Shin, Goo-Hwan | - |
dc.contributor.localauthor | Myung, Noh-Hoon | - |
dc.contributor.nonIdAuthor | Kim, Ee-Eul | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | Total ionizing dose | - |
dc.subject.keywordAuthor | Space radiation | - |
dc.subject.keywordAuthor | Serially programmable clock source | - |
dc.subject.keywordAuthor | Frequency | - |
dc.subject.keywordAuthor | Current | - |
dc.subject.keywordPlus | MEMORY | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.