AC Microplasma Device With a Cylindrical Hollow Electrode for Improving Luminous Efficacy

Cited 1 time in webofscience Cited 0 time in scopus
  • Hit : 412
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorMun, JHko
dc.contributor.authorKim, SHko
dc.contributor.authorChoi, Kyung Cheolko
dc.date.accessioned2013-03-11T05:04:12Z-
dc.date.available2013-03-11T05:04:12Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2009-09-
dc.identifier.citationIEEE TRANSACTIONS ON ELECTRON DEVICES, v.56, pp.1930 - 1934-
dc.identifier.issn0018-9383-
dc.identifier.urihttp://hdl.handle.net/10203/98319-
dc.description.abstractIn this paper, a device utilizing the hollow cathode discharge is demonstrated to diagnose the possibility of improving luminous efficacy of a microplasma device. A series of experiments is conducted by measuring luminous efficacy, which is an important factor in display devices, in accordance with specifications of the cylindrical hollow and gas pressure. The proposed structure has two electrodes, and one of them contained a cylindrical hole and is called a hollow electrode. The hollow electrode works as either a cathode or an anode alternately due to the ac operating conditions. When the hollow electrode operated as a cathode, the luminous efficacy is higher than that of the anode case, and this tendency is observed consistently throughout all experiments. Moreover, from the measurement results on the tendency of luminous efficacy in terms of hole specifications, different aspects of luminous efficacy are obtained, depending on whether the variation is in the diameter or in the depth. In case of the diameter, the luminous efficacy is improved when p . D (i.e., the product of the gas pressure and the diameter of the cylindrical hole) is less than one Torr . cm. In the case of the depth, the maximum value of luminous efficacy exists at the certain p . d (i.e., the product of the gas pressure and the depth of the cylindrical hole).-
dc.languageEnglish-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectPLASMA DISPLAY PANELS-
dc.subjectCATHODE DISCHARGES-
dc.subjectHIGH-PRESSURE-
dc.subjectEFFICIENCY-
dc.titleAC Microplasma Device With a Cylindrical Hollow Electrode for Improving Luminous Efficacy-
dc.typeArticle-
dc.identifier.wosid000269154500017-
dc.identifier.scopusid2-s2.0-69549116104-
dc.type.rimsART-
dc.citation.volume56-
dc.citation.beginningpage1930-
dc.citation.endingpage1934-
dc.citation.publicationnameIEEE TRANSACTIONS ON ELECTRON DEVICES-
dc.identifier.doi10.1109/TED.2009.2026515-
dc.contributor.localauthorChoi, Kyung Cheol-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorHollow cathode discharge-
dc.subject.keywordAuthorluminous efficacy-
dc.subject.keywordAuthormicroplasma-
dc.subject.keywordAuthorplasma display-
dc.subject.keywordPlusPLASMA DISPLAY PANELS-
dc.subject.keywordPlusCATHODE DISCHARGES-
dc.subject.keywordPlusHIGH-PRESSURE-
dc.subject.keywordPlusEFFICIENCY-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0