Experimental estimation of the fallout size and reinforcement design of a tunnel under excavation

Cited 11 time in webofscience Cited 0 time in scopus
  • Hit : 324
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, JSko
dc.contributor.authorSagong, Mko
dc.contributor.authorCho, Gye-Chunko
dc.contributor.authorChoo, SYko
dc.date.accessioned2013-03-09T16:50:19Z-
dc.date.available2013-03-09T16:50:19Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2010-09-
dc.identifier.citationTUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, v.25, no.5, pp.518 - 525-
dc.identifier.issn0886-7798-
dc.identifier.urihttp://hdl.handle.net/10203/96908-
dc.description.abstractA number of cylindrical fallouts were observed in a tunnel under construction and temporary grouting as well as immediate backfilling was performed in order to control cavity expansion. The exact dimension of the largest fallout, i.e., height, cannot be measured due to limited access to the site and, therefore, experimental as well as empirical approaches were employed to estimate the fallout size. Additional boreholes were drilled immediately after the installation of permanent reinforcement and the accuracy of the proposed Tunnel Electromagnetic Prospecting System (TEPS), a non-destructive experimental testing method used to estimate the fallout volume, is verified with borehole core data. It is found that the empirical approach based on a bulking factor is easy to apply if a reference value is available. It is also proven that the TEPS method, which is fairly simple and inexpensive during the test process, gives satisfactory results when compared with borehole data. Finally, an effective reinforcement design is considered and the safety of the reinforced fallout area is evaluated through numerical analysis. Future work will be concentrated on the refinement of the measured data from TEPS and the reinforcement effect of the auxiliary techniques utilized in the fallout area. (C) 2010 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleExperimental estimation of the fallout size and reinforcement design of a tunnel under excavation-
dc.typeArticle-
dc.identifier.wosid000279532800003-
dc.identifier.scopusid2-s2.0-77953356685-
dc.type.rimsART-
dc.citation.volume25-
dc.citation.issue5-
dc.citation.beginningpage518-
dc.citation.endingpage525-
dc.citation.publicationnameTUNNELLING AND UNDERGROUND SPACE TECHNOLOGY-
dc.identifier.doi10.1016/j.tust.2010.02.011-
dc.contributor.localauthorCho, Gye-Chun-
dc.contributor.nonIdAuthorLee, JS-
dc.contributor.nonIdAuthorSagong, M-
dc.contributor.nonIdAuthorChoo, SY-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorFallout-
dc.subject.keywordAuthorNDT-
dc.subject.keywordAuthorBulking factor-
dc.subject.keywordAuthorTunnel reinforcement-
dc.subject.keywordPlusROCK-
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 11 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0