Evaluation of error detection coverage and fault-tolerance of digital plant protection system in nuclear power plants

Cited 19 time in webofscience Cited 0 time in scopus
  • Hit : 542
  • Download : 0
Recently, traditional analog-based safety-related instrumentation and control (I&C) systems in nuclear power plants (NPPs) have been replaced with modern digital-based systems. Due to the digitalization of nuclear I&C systems, the safety assessment has become a major issue, as it is crucial to the system's reliability. In the safety assessment of the digitalized system, evaluation of error detection coverage and fault-tolerance are critical factors. For the evaluation, we use C++ based hardware description instead of a board with integrated circuit components. We select the digital plant protection system (DPPS) in NPPs as a target system. Permanent fault is used as a possible fault in the system and some error detection methods are used to detect errors. From the experiment, we confirmed that the proposed approach can evaluate the error detection coverage and the fault-tolerance of DPPS in NPPs. (c) 2006 Elsevier Ltd. All rights reserved.
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Issue Date
2006-04
Language
English
Article Type
Article
Keywords

INJECTION; VHDL

Citation

ANNALS OF NUCLEAR ENERGY, v.33, no.6, pp.544 - 554

ISSN
0306-4549
DOI
10.1016/j.anucene.2006.01.003
URI
http://hdl.handle.net/10203/92367
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 19 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0