Time-dependent measurements of flame temperature and the OH radical in the unsteady extinction of non-premixed flames

Cited 5 time in webofscience Cited 0 time in scopus
  • Hit : 270
  • Download : 0
The extinction point, time-dependent flame temperature, relative [OH], and the instantaneous luminosity of a flame during the unsteady extinction process were measured in non-premixed counterflow flames, and characteristics of each parameter near the extinction limit were investigated. We found that the unsteady extinction point is much higher than the steady extinction point and OH radical is a more adequate indicator of extinction than temperature, especially for turbulent and unsteady flames. (c) 2005 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
Publisher
ELSEVIER SCIENCE INC
Issue Date
2005-04
Language
English
Article Type
Article
Keywords

COUNTERFLOW DIFFUSION FLAMES; RAYLEIGH-SCATTERING; JET FLAMES; VELOCITY; SCALAR

Citation

COMBUSTION AND FLAME, v.141, no.1-2, pp.186 - 190

ISSN
0010-2180
DOI
10.1016/j.combustflame.2005.01.001