DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, TG | ko |
dc.contributor.author | Cho, Young-Ho | ko |
dc.date.accessioned | 2013-03-08T03:03:11Z | - |
dc.date.available | 2013-03-08T03:03:11Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2005-10 | - |
dc.identifier.citation | JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, v.14, pp.1031 - 1038 | - |
dc.identifier.issn | 1057-7157 | - |
dc.identifier.uri | http://hdl.handle.net/10203/91930 | - |
dc.description.abstract | In this paper, we present the design, fabrication, and experimental results of 4-bit digital microinjectors, whose ejected droplet volumes are adjusted by the digital operation of a 4-bit microheater array. We design the reference microinjectors as well as its comparative test structures. In the fabrication process, we use a five-mask micromachining process and the total chip size of the fabricated microinjector is 7640 pm x 5260 mu m. We observe the microbubble generation and collapse on the microheater array. The microbubbles initiate and grow individually on top of each operating microheater, however the microbubbles merge together before collapse. We measure the ejected droplet volumes and velocities, which are adjusted from 12.1 similar to 55.6 pl and 2.3 similar to 15.7 m/s, respectively, depending on the 15 possible combinations of 4-bit microheater array. We also experimentally characterize the effect of geometric variation including the microbeater size, intermicroheater gap, microchannel width and sequential operation of microheater array on the ejected droplet volume and velocity. Thus, the present microinjector has a potential for application to the high-resolution inkjet printers with multiple gray levels or high-precision fluid injectors with variable volume control. | - |
dc.language | English | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | BUBBLE-GROWTH | - |
dc.subject | JET | - |
dc.subject | MODEL | - |
dc.title | A four-bit digital microinjector using microheater array for adjusting the ejected droplet volume | - |
dc.type | Article | - |
dc.identifier.wosid | 000232571000017 | - |
dc.identifier.scopusid | 2-s2.0-27644471432 | - |
dc.type.rims | ART | - |
dc.citation.volume | 14 | - |
dc.citation.beginningpage | 1031 | - |
dc.citation.endingpage | 1038 | - |
dc.citation.publicationname | JOURNAL OF MICROELECTROMECHANICAL SYSTEMS | - |
dc.identifier.doi | 10.1106/JMEMS.2005.851864 | - |
dc.contributor.localauthor | Cho, Young-Ho | - |
dc.contributor.nonIdAuthor | Kang, TG | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | droplet volume adjusting | - |
dc.subject.keywordAuthor | inkjet printer | - |
dc.subject.keywordAuthor | microheater array | - |
dc.subject.keywordAuthor | microinjector | - |
dc.subject.keywordPlus | BUBBLE-GROWTH | - |
dc.subject.keywordPlus | JET | - |
dc.subject.keywordPlus | MODEL | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.