입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동Microstructure and corrosion behavior of various grain size Cp-Ti

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 620
  • Download : 0
DC FieldValueLanguage
dc.contributor.author이승우ko
dc.contributor.author김윤종ko
dc.contributor.author류재경ko
dc.contributor.author김원수ko
dc.contributor.author박중근ko
dc.contributor.author김택남ko
dc.date.accessioned2013-03-08T02:35:42Z-
dc.date.available2013-03-08T02:35:42Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2005-09-
dc.identifier.citation한국재료학회지, v.15, no.9, pp.585 - 588-
dc.identifier.issn1225-0562-
dc.identifier.urihttp://hdl.handle.net/10203/91854-
dc.description.abstractTitanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.-
dc.languageKorean-
dc.publisher한국재료학회-
dc.title입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동-
dc.title.alternativeMicrostructure and corrosion behavior of various grain size Cp-Ti-
dc.typeArticle-
dc.type.rimsART-
dc.citation.volume15-
dc.citation.issue9-
dc.citation.beginningpage585-
dc.citation.endingpage588-
dc.citation.publicationname한국재료학회지-
dc.contributor.localauthor박중근-
dc.contributor.nonIdAuthor이승우-
dc.contributor.nonIdAuthor김윤종-
dc.contributor.nonIdAuthor류재경-
dc.contributor.nonIdAuthor김원수-
dc.contributor.nonIdAuthor김택남-