A high isolated coupled-line passive circulator for UHF RFID reader

Cited 13 time in webofscience Cited 15 time in scopus
  • Hit : 391
  • Download : 0
A coupled-line passive circulator is proposed for improving the TX/RX isolation of the UHF radio frequency identification (RFID) reader. The increased isolation is realized by generating and adding the canceling signal to the leakage. The input return loss of the reader antenna, which can degrade TX-to-RX isolation, as well as the inherently imperfect isolation characteristic of a coupled-line directional coupler, are included in the design of the coupled-line passive circulator. The proposed coupler exhibits up to 60-dB isolation characteristic with the mismatch of the employed reader antenna. The performance comparison between the proposed and tire conventional coupled-line directional couplers shows a significant improvement in the leakage-to-signal ratio by up to 35 dB. (C) 2008 Wiley Periodicals, Inc.
Publisher
WILEY-BLACKWELL, COMMERCE PLACE
Issue Date
2008-10
Language
English
Article Type
Article
Citation

MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, v.50, no.10, pp.2597 - 2600

ISSN
0895-2477
DOI
10.1002/mop.23705
URI
http://hdl.handle.net/10203/86400
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 13 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike