Grangeat-type helical half-scan computerized tomography algorithm for reconstruction of a short object

Cited 5 time in webofscience Cited 4 time in scopus
  • Hit : 306
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee S.W.ko
dc.contributor.authorWang G.ko
dc.date.accessioned2013-03-03T20:26:28Z-
dc.date.available2013-03-03T20:26:28Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2004-
dc.identifier.citationMEDICAL PHYSICS, v.31, no.1, pp.4 - 16-
dc.identifier.issn0094-2405-
dc.identifier.urihttp://hdl.handle.net/10203/80294-
dc.description.abstractCurrently, cone-beam computerized tomography (CT) and micro-CT scanners are under rapid development for major biomedical applications. Half-scan cone-beam image reconstruction algorithms assume only part of a scanning turn, and are advantageous in terms of temporal resolution and image artifacts. While the existing half-scan cone-beam algorithms are in the Feldkamp framework, we have published a half-scan algorithm in the Grangeat framework for a circular trajectory [Med. Phys. 30, 689-700 (2003)]. In this paper, we extend our previous work to a helical case without data truncation. We modify the Grangeat's formula for utilization and estimation of Radon data. Specifically, we categorize each characteristic point in the Radon space into singly, doubly, triply sampled, and shadow regions, respectively. A smooth weighting strategy is designed to compensate for data redundancy and inconsistency. In the helical half-scan case, the concepts of projected trajectories and transition points on meridian planes are introduced to guide the design of weighting functions. Then, the shadow region is recovered via linear interpolation after smooth weighting. The Shepp-Logan phantom is used to verify the correctness of the formulation, and demonstrate the merits of the Grangeat-type half-scan algorithm. Our Grangeat-type helical half-scan algorithm is not only valuable for quantitative and/or dynamic biomedical applications of CT and micro-CT, but also serves as an intermediate step towards solving the long object problem. (C) 2004 American Association of Physicists in Medicine.-
dc.languageEnglish-
dc.publisherAMER ASSOC PHYSICISTS MEDICINE AMER INST PHYSICS-
dc.subjectCONE-BEAM RECONSTRUCTION-
dc.subjectCT-
dc.subjectBACKPROJECTION-
dc.subjectFORMULA-
dc.subjectDETECTOR-
dc.titleGrangeat-type helical half-scan computerized tomography algorithm for reconstruction of a short object-
dc.typeArticle-
dc.identifier.wosid000188383500002-
dc.identifier.scopusid2-s2.0-1642454607-
dc.type.rimsART-
dc.citation.volume31-
dc.citation.issue1-
dc.citation.beginningpage4-
dc.citation.endingpage16-
dc.citation.publicationnameMEDICAL PHYSICS-
dc.identifier.doi10.1118/1.1625115-
dc.contributor.localauthorLee S.W.-
dc.contributor.nonIdAuthorWang G.-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorhalf-scan-
dc.subject.keywordAuthorGrangeat-type reconstruction-
dc.subject.keywordAuthorcone-beam CT-
dc.subject.keywordAuthorhelical CT-
dc.subject.keywordPlusCONE-BEAM RECONSTRUCTION-
dc.subject.keywordPlusCT-
dc.subject.keywordPlusBACKPROJECTION-
dc.subject.keywordPlusFORMULA-
dc.subject.keywordPlusDETECTOR-
Appears in Collection
RIMS Journal Papers
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 5 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0