DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Sang Done | ko |
dc.date.accessioned | 2013-03-03T16:49:45Z | - |
dc.date.available | 2013-03-03T16:49:45Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2003-01 | - |
dc.identifier.citation | KOREAN JOURNAL OF CHEMICAL ENGINEERING, v.20, no.1, pp.163 - 168 | - |
dc.identifier.issn | 0256-1115 | - |
dc.identifier.uri | http://hdl.handle.net/10203/79545 | - |
dc.description.abstract | We studied the hydrodynamic characteristics of a three-phase inverse fluidized bed made of a transparent acrylic column of 0.115 in inner diameter and 2 in heights. Air, water and polyethylene particles were used as the gas, liquid and solid phase, respectively. We used both hydrophobic low density polyethylene (LDPE) and hydrophilic LDPE as solid phase, and distilled water as liquid phase, and filtered air as gas phase. The LDPE was chemically treated by chlorosulfonic acid to change the surface property from hydrophobic to hydrophilic. We tried to solely investigate the effect of the surface hydrophilicity of polymeric particles on the phase holdup and the critical fluidization velocity of three-phase inverse fluidization. Thus, we measured the static pressure and eventually observed critical fluidization velocity. Critical fluidization velocity became smaller in case of using MDPE hydrophobic particles than LDPE hydrophilic particles. This was thought to be due to the retardation of rising bubbles near hydrophobic particles and, subsequently, the increase of gas hold-up. | - |
dc.language | English | - |
dc.publisher | Springer | - |
dc.subject | LIQUID-SOLID FLUIDIZATION | - |
dc.subject | REACTORS | - |
dc.subject | GAS | - |
dc.subject | HYDRODYNAMICS | - |
dc.title | Phase Holdup and Critical Fluidization Velocity in a Three-Phase Inverse Fluidized Bed | - |
dc.type | Article | - |
dc.identifier.wosid | 000181050100028 | - |
dc.identifier.scopusid | 2-s2.0-0037238914 | - |
dc.type.rims | ART | - |
dc.citation.volume | 20 | - |
dc.citation.issue | 1 | - |
dc.citation.beginningpage | 163 | - |
dc.citation.endingpage | 168 | - |
dc.citation.publicationname | KOREAN JOURNAL OF CHEMICAL ENGINEERING | - |
dc.contributor.localauthor | Kim, Sang Done | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | inverse fluidized bed | - |
dc.subject.keywordAuthor | hydrophobic | - |
dc.subject.keywordAuthor | hydrophilic | - |
dc.subject.keywordAuthor | critical fluidization velocity | - |
dc.subject.keywordPlus | LIQUID-SOLID FLUIDIZATION | - |
dc.subject.keywordPlus | REACTORS | - |
dc.subject.keywordPlus | GAS | - |
dc.subject.keywordPlus | HYDRODYNAMICS | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.