DC Field | Value | Language |
---|---|---|
dc.contributor.author | 인세환 | ko |
dc.contributor.author | 정상권 | ko |
dc.date.accessioned | 2013-03-03T10:04:19Z | - |
dc.date.available | 2013-03-03T10:04:19Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2002 | - |
dc.identifier.citation | 한국초전도.저온공학회논문지, v.4, no.1, pp.66 - 72 | - |
dc.identifier.issn | 1229-3008 | - |
dc.identifier.uri | http://hdl.handle.net/10203/78310 | - |
dc.description.abstract | This paper describes numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas (low and a copper lead and temperature dependent properties of helium gas, copper and stainless steel. This numerical modeling was compensated and validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor was suggested for the current leads under pulse operation through this modeling, which can significantly reduce heat input to a cryostat. | - |
dc.language | Korean | - |
dc.publisher | 한국초전도.저온공학회 | - |
dc.title | 펄스 모드로 작동하는 증기냉각 전류 도입선에 관한 연구 | - |
dc.title.alternative | Investigation on vapor-cooled current leads operating in pulse mode | - |
dc.type | Article | - |
dc.type.rims | ART | - |
dc.citation.volume | 4 | - |
dc.citation.issue | 1 | - |
dc.citation.beginningpage | 66 | - |
dc.citation.endingpage | 72 | - |
dc.citation.publicationname | 한국초전도.저온공학회논문지 | - |
dc.contributor.localauthor | 정상권 | - |
dc.contributor.nonIdAuthor | 인세환 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.