최소분산 캡스트럼을 이용한 노이즈 속에 묻힌 임펄스 검출 방법-베어링 결함 검출에의 적용Detection of Impulse Signal in Noise Using a Minimum Variance Cepstrum -Application on Faults Detection in a Bearing System

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 401
  • Download : 0
The signals that can be obtained from rotating machines often convey the information of machine. For example, if the machine under investigation has faults, then these signals often have pulse signals, embedded in noise. Therefore the ability to detect the fault signal in noise is major concern of fault diagnosis of rotating machine, In this paper, minimum variance cepstrum (MV cepstrum) . which can easily detect impulse in noise, has been applied to detect the type of faults of ball bearing system. To test the performance of this technique. various experiments have been performed for ball bearing elements that have man made faults. Results show that minimum variance cepstrum can easily detect the periodicity due to faults and also shows the pattern of excitation by the faults.
Publisher
한국소음진동공학회
Issue Date
2000-06
Language
Korean
Citation

한국소음진동공학회논문집, v.10, no.6, pp.985 - 990

ISSN
1598-2785
URI
http://hdl.handle.net/10203/76762
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.