덕트 내부의 고차모드 수보다 적은 수의 제어음원과 마이크로폰을 이용한 덕트 방사소음 제어에 관한 연구A Study on Active Control of the Radiated Duct Noise with Insufficient Number of Control Dources and Microphones

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 332
  • Download : 0
If one wants to control the noise from a duct, then one must have sufficient number of sensors and actuators so that the control system is observable and controllable. A number of sensors and actuators for control of radiating noise from a duct have to be incorporated with the number of modes which one wants to control. These considerations motivated the present study that considers a control system which has less microphones and actuators than required. In this work, by theoretical analysis and numerical simulation, the control performance and robust reliability of such a kind of control system is investigated in terms of sound-field variables and control system variables. Then the possibility of implementation of the robust radiation power control system is verified by theoretical analysis and numerical simulation. In addition, the control performance of the control system is verified by experiment.
Publisher
한국소음진동공학회
Issue Date
1998-02
Language
Korean
Citation

한국소음진동공학회논문집, v.8, no.2, pp.283 - 288

ISSN
1598-2785
URI
http://hdl.handle.net/10203/76743
Appears in Collection
ME-Journal Papers(저널논문)