고차모드 수보다 적은 수의 제어 음원과 센서를 이용한 덕트 방사 소음 제어 시스템의 제어 성능The Control Performance of the Active Control System with Insufficient Number of Control Sources and Sensors for the Reduction of Duct Noise

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 451
  • Download : 0
When the lateral dimensions of a duct is larger than or comparable to the wavelengths of Interest, higher order modes propagate in the duct. These modes will be radiated and produce noise. A number of sensors and actuators for control of radiating noise from the duct have to be incorporated with the number of modes which one wants to control. These considerations motivated the present study that considers a control system which has less microphones and control sources than required. In this work, by theoretical analysis, the control performance of such a kind of system is investigated in terms of sound-field variables and control system variables. The possible maximum and minimum value. mean and variance of residual acoustic potential energy are derived for the set of primary sound fields.
Publisher
한국소음진동공학회
Issue Date
1998-06
Language
Korean
Citation

한국소음진동공학회논문집, v.8, no.6, pp.1030 - 1036

ISSN
1598-2785
URI
http://hdl.handle.net/10203/76670
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0