Long-term behaviour of square concrete-filled steel tubular columns under axial service loads

Cited 32 time in webofscience Cited 0 time in scopus
  • Hit : 569
  • Download : 2
This paper presents experimental and analytical studies on the long-term behaviour of rectangular concrete-filled steel tubular (CFT) columns under central axial loading. Four loading cases are considered in this study: ( a) a load applied simultaneously on both the inner concrete and steel tube (SCE); (b) a load applied only on the inner core concrete (CE); ( c) a load applied on the steel tube and three quarters of the inner concrete (SCQ); and (d) a load applied on the steel tube and half of the inner concrete (SCH). The last two loading cases ( SCQ and SCH) simulate a diaphragm installed in the steel tube. Specimens measuring 600 mm in length were tested for the first two loading cases ( SCE and CE), and specimens of three different lengths, 600, 900 and 1200 mm, were tested for the last two loading cases in order to investigate the effect of the diaphragm size and the length of the specimen on the long-term behaviour of rectangular CFT columns. In addition to the experimental study, three-dimensional finite element models for each specimen were established and verified from a comparison of the test data and the analysis results. From the test and analysis results, a number of conclusions can be drawn. The magnitude of long-term deformation of a CFT column with a diaphragm that covers more than a half of the cross-sectional area of the inner concrete is identical with that of a column under a load applied simultaneously on the entire section of the steel tube and the inner concrete. The diaphragm confines the lateral deformation of the end surface of the column, and its influence range is limited only to the end part of the column, meaning it is limited only from the surface to a depth as long as the width of the CFT column. The confinement effect and stress variation along the longitudinal axis do not occur except in the influence range of the diaphragm. In the case of loading only at the inner concrete, the inner concrete is confined at the corner by the steel tube, and the slip between the inner concrete and the steel tube increases over time.
Publisher
THOMAS TELFORD PUBLISHING
Issue Date
2007-02
Language
English
Article Type
Article
Keywords

TUBES

Citation

MAGAZINE OF CONCRETE RESEARCH, v.59, no.1, pp.53 - 68

ISSN
0024-9831
URI
http://hdl.handle.net/10203/7618
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 32 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0