Analysis of a gas-particle direct-contact heat exchanger with two-phase radiation effect

Cited 16 time in webofscience Cited 0 time in scopus
  • Hit : 667
  • Download : 67
A direct-contact heat exchange using particle-suspended gas as a heat transfer medium is analyzed with an extended emphasis on the radiation, i.e., considering the radiation by both gas and particles. While the Runge-Kutta method is used for a numerical analysis of the momentum and energy equations, the finite volume method is utilized to solve the radiative transfer equation. The present study shows a notable effect by the gas radiation in addition to the particle radiation, especially when varying the chamber length as well as the gas and particle mass flow rate. When the gas and particle mass pow rate is raised, the gas temperature in the particle heater increases as the gas absorption coefficient increases, which is different from the results for the small-scale heat exchanger. However, the scattering effects by particles were found to be insignificant.
Publisher
HEMISPHERE PUBL CORP
Issue Date
1998-05
Language
English
Article Type
Article
Keywords

NUMERICAL-ANALYSIS; ENCLOSURES

Citation

NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, v.33, no.7, pp.701 - 721

ISSN
1040-7782
URI
http://hdl.handle.net/10203/7032
Appears in Collection
AE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 16 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0