A methodology for benefit assessment of using in-core neutron detector signals in core protection calculator system (CPCS) for Korea standard nuclear power plants (KSNPP)

Cited 6 time in webofscience Cited 11 time in scopus
  • Hit : 662
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorHan, Sko
dc.contributor.authorKim, USko
dc.contributor.authorSeong, Poong-Hyunko
dc.date.accessioned2013-02-27T10:23:50Z-
dc.date.available2013-02-27T10:23:50Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued1999-04-
dc.identifier.citationANNALS OF NUCLEAR ENERGY, v.26, no.6, pp.471 - 488-
dc.identifier.issn0306-4549-
dc.identifier.urihttp://hdl.handle.net/10203/67970-
dc.description.abstractCore Protection Calculator System (CPCS) is a digital computer based safety system generating trip signals based on the calculation of departure from nucleate boiling ratio (DNBR) and local power density (LPD). Currently, CPCS uses ex-core detector signals for core power calculation and it has some uncertainties. In this work, a quantitative economic benefit assessment of using in-core neutron detector signals is carried out. In-core detector signals which directly measure the inside neutron flux of core are applied to CPCS to obtain more accurate power distribution profile, DNBR and LPD to reduce the calculation uncertainties. In order to improve axial power distribution calculation, piecewise cubic spline method is applied. Simulation is also carried out to verify its applicability to power distribution calculation in this work. Simulation result shows that the improved method reduces the calculational uncertainties significantly and it allows larger operational margin. It is also assured that no power reduction is required while Core Operating Limit Supervisory System (COLSS) is out-of-service when the improved method is applied. (C) 1999 Elsevier Science Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleA methodology for benefit assessment of using in-core neutron detector signals in core protection calculator system (CPCS) for Korea standard nuclear power plants (KSNPP)-
dc.typeArticle-
dc.identifier.wosid000078055500002-
dc.identifier.scopusid2-s2.0-0033117479-
dc.type.rimsART-
dc.citation.volume26-
dc.citation.issue6-
dc.citation.beginningpage471-
dc.citation.endingpage488-
dc.citation.publicationnameANNALS OF NUCLEAR ENERGY-
dc.identifier.doi10.1016/S0306-4549(98)00063-2-
dc.contributor.localauthorSeong, Poong-Hyun-
dc.contributor.nonIdAuthorHan, S-
dc.contributor.nonIdAuthorKim, US-
dc.type.journalArticleArticle-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 6 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike