3-LEVEL SPACE VECTOR PWM IN LOW-INDEX MODULATION REGION AVOIDING NARROW PULSE PROBLEM

Cited 49 time in webofscience Cited 0 time in scopus
  • Hit : 877
  • Download : 1701
In using GTO, a few hundreds micro seconds longer than specified pulse width must be guaranteed for safety for each device to commutate with its inherent gate current Sequences. This paper describes the mechanism of generating undesirable narrow pulses in conventional three-level space vector PWM and suggests two new algorithms of space vector PWM using Non-Nearest three and four vectors in a control period to avoid such a narrow pulse problem. Experimental verifications for the suggested algorithms are also presented.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
1994-09
Language
English
Article Type
Article
Citation

IEEE TRANSACTIONS ON POWER ELECTRONICS, v.9, no.5, pp.481 - 486

ISSN
0885-8993
URI
http://hdl.handle.net/10203/6637
Appears in Collection
EE-Journal Papers(저널논문)