MEASUREMENT OF THE TEMPERATURE AND THE PUMPING UNIFORMITY INSIDE A ND-YAG ROD BY AN INTERFEROMETRIC METHOD

Cited 1 time in webofscience Cited 0 time in scopus
  • Hit : 335
  • Download : 323
The thermal behavior of a Nd:YAG laser rod under flashlamp pumping has been investigated experimentally using a very simple interferometric technique. The degree of pumping uniformity and the heat generation rate inside the rod was evaluated for single pulse pumping. The temperature increase at the center of the rod under a high repetition rate pulsed operation was also measured,and this result is used to deduce the surface heat transfer coefficient.
Publisher
AMER INST PHYSICS
Issue Date
1991-04
Language
English
Article Type
Article
Keywords

THERMAL PROFILE; LASERS

Citation

APPLIED PHYSICS LETTERS, v.58, no.17, pp.1810 - 1812

ISSN
0003-6951
DOI
10.1063/1.105096