(A) study on the effect of various spacer grids on CHF in 2*2 rod bundle with R-134aR-134a를 이용한 2*2 봉다발에서 다양한 지지격자가 임계열유속에 미치는 영향에 관한 연구

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 516
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorChang, Soon-Heung-
dc.contributor.advisor장순흥-
dc.contributor.authorShin, Byung-Soo-
dc.contributor.author신병수-
dc.date.accessioned2011-12-14T08:16:39Z-
dc.date.available2011-12-14T08:16:39Z-
dc.date.issued2003-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=180195&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/49459-
dc.description학위논문(석사) - 한국과학기술원 : 원자력및양자공학과, 2003.2, [ vii, 50 p. ]-
dc.description.abstractExperimental investigation was performed using the 2*2 rod bundle in order to find out the effect of spacer grid on CHF with R-134a. The rod diameter of test section is 9.7mm. Rod pitch is 12.95mm. An outside-line of flow channel is 25.7mm. As test spacer grids, three different types of spacer grid that was applied for a patent by KAERI and V-5H were selected. Experimental conditions are as follows: Mass flux is from 1000 to 1800 kg/㎡s, inlet temperature is from 10 to 20℃, and inlet pressure is 20 bar. Flow structure experiment was also performed with single-phase water at room temperature and atmospheric pressure. The result of CHF experiment was explained through this experiment qualitatively. In this experiment, using LDV, we measured axial and lateral velocity and turbulent intensity along the centerline to find out the swirl magnitude and turbulent kinetic energy. And using DP cell, pressure drop was also measured. Consequently, the swirl flow and turbulent level forming by spacer grid and mixing vane contributed to the CHF enhancement. The ratio of enhancement was changed as the distance from spacer grid. And we also confirmed that a blockage area was an important parameter in view of pressure drop.eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectCritical Heat Flux-
dc.subjectSpacer Grid-
dc.subjectCHF-
dc.subject봉다발-
dc.subject임계열유속-
dc.subject지지격자-
dc.subjectRod Bundle-
dc.title(A) study on the effect of various spacer grids on CHF in 2*2 rod bundle with R-134a-
dc.title.alternativeR-134a를 이용한 2*2 봉다발에서 다양한 지지격자가 임계열유속에 미치는 영향에 관한 연구-
dc.typeThesis(Master)-
dc.identifier.CNRN180195/325007-
dc.description.department한국과학기술원 : 원자력및양자공학과, -
dc.identifier.uid020013311-
dc.contributor.localauthorShin, Byung-Soo-
dc.contributor.localauthor신병수-
Appears in Collection
NE-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0