dc.description | 학위논문(석사) - 한국과학기술원 : 원자력공학과, 1999.2, [ vi, 55 p. ] | - |
dc.description.abstract | Impedance matching in a large-area Transformer Coupled Plasma source was studied. At first, automatic impedance matching was planned, so some ideas for automatic impedance matching are presented. But, we discovered that in our experimental system there is only one impedance matching condition and it is irrelevant to plasma status. Because the automatic impedance matching in our experimental system is meaningless, we tried to find the only impedance matching condition. During the impedance matching experiment, a discrepancy between theoretical calculations and experimental results was found. So, we introduced a new way of understanding our system using a modified model which is based on the assumption that inductance and capacitances have a dependency on frequency, and the modified model explained the experimental results well. With this modified model, load impedances of the power supply in various configurations were calculated and used to analyze the data from plasma experiments. In our experimental system, maximum plasma density was found near 500Ω load impedance regardless of the condition of a plasma. Thus, we concluded that the only impedance matching condition is located near 500Ω load impedance. Furthermore, plasma control is possible based on the experimental data. | eng |
dc.language | eng | - |
dc.publisher | 한국과학기술원 | - |
dc.subject | Impedance matching | - |
dc.subject | Transformer coupled plasma | - |
dc.subject | TCP 플라즈마원 | - |
dc.subject | 임피던스 정합 | - |
dc.title | (A) study on impedance matching in a large-area transformer coupled plasma source | - |
dc.title.alternative | 대면적 transformer coupled plasma원에서의 임피던스 정합에 관한 연구 | - |
dc.type | Thesis(Master) | - |
dc.identifier.CNRN | 150475/325007 | - |
dc.description.department | 한국과학기술원 : 원자력공학과, | - |
dc.identifier.uid | 000973082 | - |
dc.contributor.localauthor | Kim, Man-Cheol | - |
dc.contributor.localauthor | 김만철 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.