(A) study on the sensitivity of self-powered neutron detectors(SPNDs)자기 출력형 중성자 검출기의 민감도에 관한 연구

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 512
  • Download : 0
Self-Powered Neutron Detectors(SPND) are currently used to estimate the power generation distribution and fuel burn-up in several nuclear power reactors in Korea. While they have several advantages such as small size, low cost, and relatively simple electronics required in conjunction with those usage, they have some intrinsic problems of the low level of output current, a slow response time, the rapid change of sensitivity which makes it difficult to use for a long term. In this paper, Monte Carlo simulation is accomplished to calculate the escape probability as a function of the birth position of emitted beta particle for a geometry of rhodium-based SPNDs. A simple numerical method calculates the initial generation rate of beta particles and the change of generation rate due to rhodium burn-up. Using the simulation result, the burn-up profile of rhodium number density and the neutron sensitivity are calculated as a function of burn-up time in reactors. The sensitivity of the SPND decreases non-linearly due to the high absorption cross-section and the non-uniform burn-up of rhodium in the emitter rod. In addition, for improvement of some properties of rhodium-based SPNDs which are currently used, this paper presents a new material and modified geometry. From searching nuclear data, $Ag^{109}$ is chosen as a replacing material for rhodium. Silver has a low neutron absorption cross-section and a high beta energy and a low density when it is compared with rhodium. The sensitivity and the density change of silver as a function of burn-up are calculated using this method. Also, this paper compares the initial sensitivity of a solid type with its of a tube type. The initial sensitivity is increased with the new material and the tube type. Silver is also found to be used for longer time than rhodium. The method used here can be applied to the analysis of other types of SPNDs and will be useful in the optimum design of new SPNDs for long term usage.
Advisors
Cho, Gyu-Seongresearcher조규성researcher
Description
한국과학기술원 : 원자력공학과,
Publisher
한국과학기술원
Issue Date
1997
Identifier
114546/325007 / 000953453
Language
eng
Description

학위논문(석사) - 한국과학기술원 : 원자력공학과, 1997.2, [ vi, 45 p. ]

Keywords

Sensitivity; Self-powered neutron detector; 자기 출력형 중성자 검출기; 민감도

URI
http://hdl.handle.net/10203/49373
Link
http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=114546&flag=dissertation
Appears in Collection
NE-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0