Effects of the concrete crack on radiation shielding in spent fuel dry storage facility사용후핵연료 건식저장시설에서 콘크리트 균열이 방사선 차폐에 미치는 영향

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 939
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorLee, Kun-Jai-
dc.contributor.advisor이건재-
dc.contributor.authorLee, Chang-Min-
dc.contributor.author이창민-
dc.date.accessioned2011-12-14T08:06:10Z-
dc.date.available2011-12-14T08:06:10Z-
dc.date.issued2007-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=268722&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/49000-
dc.description학위논문(박사) - 한국과학기술원 : 원자력및양자공학과, 2007. 8, [ xix, 159 p. ]-
dc.description.abstractThe saturation of South Korea\`s at-reactor (AR) spent fuel storage pools has created necessity for additional spent fuel storage capacity. The Korea Hydro & Nuclear Power Company is planning to construct a MACSTOR-400 composed of reinforced concrete. In concrete structures, cracks occur due to thermal stress, hydration heat, weather, load and other reasons, and shielding performance changes according to the crack width. However, there are no design criteria providing the allowable crack size for shielding. This research presents to estimate the effect of concrete cracking on gamma-ray shielding performance in MACSTOR-400. In order to estimate the crack effect on spent fuel storage facility, this research assume the two cases ; crack effect on surface dose rate and crack effect on dose rate in site boundary. For estimating the surface dose rate according to the event by crack, two cases were assumed. One is a “Normal State,” which is based upon the assumption that crack is formed. The other is a “Abnormal State,” which assumes that spalling by reinforcement corrosion occurs. Normal state is based on deduction of a correlation between intensity and crack width through experiments. For the experiment, the measuring system is designed and fabricated. With this system, test is carried out and the accuracy is estimated through comparing result of simulation with result of experiment. It is confirmed that result of simulation and experiment has a similar trend with 5% error. The surface dose rate increased logarithmically according to the increase in crack width. According to the results, if the thickness of shield is over 30cm and the crack width is 0.4mm, crack effect is under 10%. If the thickness of wall is 90cm and the crack width is 0.4mm in MACSTOR-400, because it is estimated that surface dose rate exceed the design criteria, the proper measures are demanded. The present results are used to formulate an attenuation equation for gamma rays in a concrete st...eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectspent fuel-
dc.subjectdry storage-
dc.subjectcrack effect-
dc.subjectspalling effect-
dc.subjectradiation shielding-
dc.subjectMACSTOR-400-
dc.subjectconcrete crack-
dc.subjectcollimator-
dc.subjectsurface dose rate-
dc.subject사용후핵연료-
dc.subject건식저장-
dc.subject균열 효과-
dc.subject스폴링효과-
dc.subject방사선 차폐-
dc.subject멕스터-400-
dc.subject콘크리트 균열-
dc.subject콜리메이터-
dc.subject표면선량율-
dc.titleEffects of the concrete crack on radiation shielding in spent fuel dry storage facility-
dc.title.alternative사용후핵연료 건식저장시설에서 콘크리트 균열이 방사선 차폐에 미치는 영향-
dc.typeThesis(Ph.D)-
dc.identifier.CNRN268722/325007 -
dc.description.department한국과학기술원 : 원자력및양자공학과, -
dc.identifier.uid020015863-
dc.contributor.localauthorLee, Chang-Min-
dc.contributor.localauthor이창민-
Appears in Collection
NE-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.