A Synchronous-Sampling Impedance-Readout IC with Baseline-Cancellation-Based Two-Step Conversion for Fast Neural Electrical Impedance Tomography

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 49
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorSuh, Ji-Hoonko
dc.contributor.authorChoi, Haidamko
dc.contributor.authorJung, Yoontaeko
dc.contributor.authorOh, Seinko
dc.contributor.authorCho, Hyungjooko
dc.contributor.authorKoo, Nahmilko
dc.contributor.authorKim, Seong Joongko
dc.contributor.authorBae, Chisungko
dc.contributor.authorHa, Sohmyungko
dc.contributor.authorJe, Minkyuko
dc.date.accessioned2023-09-01T00:00:22Z-
dc.date.available2023-09-01T00:00:22Z-
dc.date.created2023-02-24-
dc.date.issued2022-11-
dc.identifier.citation2022 IEEE Asian Solid-State Circuits Conference, A-SSCC 2022-
dc.identifier.urihttp://hdl.handle.net/10203/312091-
dc.description.abstractElectrical impedance tomography (EIT) is widely used for functional imaging of the bio-impedance of body parts for various applications, such as lung ventilation monitoring [1]. It was recently shown that 'fast neural EIT' with far enhanced temporal resolution (frame rate) can provide the neural activity monitoring and functional localization of the active peripheral nerve at the same time [2]. In an EIT system, to reconstruct an impedance tomography image (Fig. 1(a)), an AC current is injected from a current generator (ICG) into the target bioimpedance network ZBIO through an electrode pair (channel) in a rotational manner, while demodulating the voltages appeared at all the other channels. The I/Q demodulation is the most popular way to extract the resistance and reactance information of ZBIO [1]. For the neural EIT, however, this method cannot support a high enough frame rate, failing to acquire neural activities, mainly due to the downconversion to DC and low-pass filtering. As shown in Fig. 1(a), many cycles of the AC input signal are needed for the I and Q outputs to be well settled to their final values. A higher excitation frequency (fCG) can be used for faster settling in conventional applications, but in the neural EIT, fCG should be <20kHz for high SNR image acquisition [2]. Alternatively, peak detection can be used [3], but it needs a much faster sampling clock than fCG, consuming a large dynamic power in all the demodulation channels.-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleA Synchronous-Sampling Impedance-Readout IC with Baseline-Cancellation-Based Two-Step Conversion for Fast Neural Electrical Impedance Tomography-
dc.typeConference-
dc.identifier.scopusid2-s2.0-85146591018-
dc.type.rimsCONF-
dc.citation.publicationname2022 IEEE Asian Solid-State Circuits Conference, A-SSCC 2022-
dc.identifier.conferencecountryCH-
dc.identifier.conferencelocationTaipei-
dc.identifier.doi10.1109/A-SSCC56115.2022.9980820-
dc.contributor.localauthorJe, Minkyu-
dc.contributor.nonIdAuthorChoi, Haidam-
dc.contributor.nonIdAuthorJung, Yoontae-
dc.contributor.nonIdAuthorOh, Sein-
dc.contributor.nonIdAuthorCho, Hyungjoo-
dc.contributor.nonIdAuthorKoo, Nahmil-
dc.contributor.nonIdAuthorKim, Seong Joong-
dc.contributor.nonIdAuthorBae, Chisung-
dc.contributor.nonIdAuthorHa, Sohmyung-
Appears in Collection
EE-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0