Automatic and Reliable Quantification of Tonic Dopamine Concentrations In Vivo Using a Novel Probabilistic Inference Method

Cited 3 time in webofscience Cited 0 time in scopus
  • Hit : 88
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, Jaekyungko
dc.contributor.authorBarath, Abhijeet S.ko
dc.contributor.authorRusheen, Aaron E.ko
dc.contributor.authorCabrera, Juan M. Rojasko
dc.contributor.authorPrice, J. Blairko
dc.contributor.authorShin, Hojinko
dc.contributor.authorGoyal, Abhinavko
dc.contributor.authorYuen, Jason W.ko
dc.contributor.authorJondal, Danielle E.ko
dc.contributor.authorBlaha, Charles D.ko
dc.contributor.authorLee, Kendall H.ko
dc.contributor.authorJang, Dong Pyoko
dc.contributor.authorOh, Yoonbaeko
dc.date.accessioned2023-07-20T05:00:18Z-
dc.date.available2023-07-20T05:00:18Z-
dc.date.created2023-07-20-
dc.date.issued2021-03-
dc.identifier.citationACS OMEGA, v.6, no.10, pp.6607 - 6613-
dc.identifier.urihttp://hdl.handle.net/10203/310705-
dc.description.abstractDysregulation of the neurotransmitter dopamine (DA) is implicated in several neuropsychiatric conditions. Multiple-cyclic square-wave voltammetry (MCSWV) is a state-of-the-art technique for measuring tonic DA levels with high sensitivity (<5 nM), selectivity, and spatiotemporal resolution. Currently, however, analysis of MCSWV data requires manual, qualitative adjustments of analysis parameters, which can inadvertently introduce bias. Here, we demonstrate the development of a computational technique using a statistical model for standardized, unbiased analysis of experimental MCSWV data for unbiased quantification of tonic DA. The oxidation current in the MCSWV signal was predicted to follow a lognormal distribution. The DA-related oxidation signal was inferred to be present in the top 5% of this analytical distribution and was used to predict a tonic DA level. The performance of this technique was compared against the previously used peak-based method on paired in vivo and post-calibration in vitro datasets. Analytical inference of DA signals derived from the predicted statistical model enabled high-fidelity conversion of the in vivo current signal to a concentration value via in vitro post-calibration. As a result, this technique demonstrated reliable and improved estimation of tonic DA levels in vivo compared to the conventional manual post-processing technique using the peak current signals. These results show that probabilistic inference-based voltammetry signal processing techniques can standardize the determination of tonic DA concentrations, enabling progress toward the development of MCSWV as a robust research and clinical tool.-
dc.languageEnglish-
dc.publisherAMER CHEMICAL SOC-
dc.titleAutomatic and Reliable Quantification of Tonic Dopamine Concentrations In Vivo Using a Novel Probabilistic Inference Method-
dc.typeArticle-
dc.identifier.wosid000631101200011-
dc.identifier.scopusid2-s2.0-85103376613-
dc.type.rimsART-
dc.citation.volume6-
dc.citation.issue10-
dc.citation.beginningpage6607-
dc.citation.endingpage6613-
dc.citation.publicationnameACS OMEGA-
dc.identifier.doi10.1021/acsomega.0c05217-
dc.contributor.localauthorKim, Jaekyung-
dc.contributor.nonIdAuthorBarath, Abhijeet S.-
dc.contributor.nonIdAuthorRusheen, Aaron E.-
dc.contributor.nonIdAuthorCabrera, Juan M. Rojas-
dc.contributor.nonIdAuthorPrice, J. Blair-
dc.contributor.nonIdAuthorShin, Hojin-
dc.contributor.nonIdAuthorGoyal, Abhinav-
dc.contributor.nonIdAuthorYuen, Jason W.-
dc.contributor.nonIdAuthorJondal, Danielle E.-
dc.contributor.nonIdAuthorBlaha, Charles D.-
dc.contributor.nonIdAuthorLee, Kendall H.-
dc.contributor.nonIdAuthorJang, Dong Pyo-
dc.contributor.nonIdAuthorOh, Yoonbae-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordPlusSCAN CYCLIC VOLTAMMETRY-
dc.subject.keywordPlusHUMAN STRIATUM-
dc.subject.keywordPlusADSORPTION-
dc.subject.keywordPlusRECEPTORS-
dc.subject.keywordPlusRELEASE-
dc.subject.keywordPlusNUCLEUS-
Appears in Collection
BS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 3 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0