Flexible pH sensor and system fabricated using PET film

Cited 4 time in webofscience Cited 0 time in scopus
  • Hit : 76
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorYun, Seok-Ohko
dc.contributor.authorCho, Hanwonko
dc.contributor.authorSuh, Ji-Hoonko
dc.contributor.authorPark, Jeong-Hoko
dc.contributor.authorChoi, Bong Gillko
dc.contributor.authorLee, Tae Jaeko
dc.contributor.authorKweon, Soon-Jaeko
dc.contributor.authorLee, Jong-Kwonko
dc.contributor.authorSeo, Chang-Hoko
dc.contributor.authorYoo, Hyung-Jounko
dc.contributor.authorKim, Choul-Youngko
dc.date.accessioned2023-07-13T01:01:36Z-
dc.date.available2023-07-13T01:01:36Z-
dc.date.created2023-07-07-
dc.date.created2023-07-07-
dc.date.issued2017-10-
dc.identifier.citation16th IEEE SENSORS Conference, ICSENS 2017, pp.1 - 3-
dc.identifier.issn1930-0395-
dc.identifier.urihttp://hdl.handle.net/10203/310467-
dc.description.abstractWe have developed a pH sensitive sensor for monitoring acidity of an infected wound area, as well as a pH meter for real-time monitoring the pH value. The pH sensor was fabricated by depositing Au and Ag on a PET film using a semiconductor process. The electrodes consist of a working electrode and a reference electrode. Here, the reference electrode was fabricated by synthesizing Polyaniline (PANI) on Ag/AgCl, and the sensor was constructed with four channels in order to measure the pH value in a wide area evenly. Then, the completed system including the pH sensor is 5×5 cm2 in size, and the measured values of pH range from 3 to 9, along with the slope of 50 mV / pH in the overall measurement.-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleFlexible pH sensor and system fabricated using PET film-
dc.typeConference-
dc.identifier.wosid000427677500058-
dc.identifier.scopusid2-s2.0-85044262375-
dc.type.rimsCONF-
dc.citation.beginningpage1-
dc.citation.endingpage3-
dc.citation.publicationname16th IEEE SENSORS Conference, ICSENS 2017-
dc.identifier.conferencecountryUK-
dc.identifier.conferencelocationGlasgow, Scotland-
dc.identifier.doi10.1109/ICSENS.2017.8233925-
dc.contributor.localauthorYoo, Hyung-Joun-
dc.contributor.nonIdAuthorYun, Seok-Oh-
dc.contributor.nonIdAuthorSuh, Ji-Hoon-
dc.contributor.nonIdAuthorPark, Jeong-Ho-
dc.contributor.nonIdAuthorChoi, Bong Gill-
dc.contributor.nonIdAuthorLee, Tae Jae-
dc.contributor.nonIdAuthorLee, Jong-Kwon-
dc.contributor.nonIdAuthorSeo, Chang-Ho-
dc.contributor.nonIdAuthorKim, Choul-Young-
Appears in Collection
EE-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0