Structural health monitoring methods for bridges using ambient vibration and impedance measurements상시진동 및 임피던스 계측을 이용한 교량 구조건전도 모니터링 기술

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 592
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorYun, Chung-Bang-
dc.contributor.advisor윤정방-
dc.contributor.authorKoo, Ki-Young-
dc.contributor.author구기영-
dc.date.accessioned2011-12-13T02:23:32Z-
dc.date.available2011-12-13T02:23:32Z-
dc.date.issued2008-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=295254&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/30593-
dc.description학위논문(박사) - 한국과학기술원 : 건설및환경공학과, 2008.2, [ xv, 112 p. ]-
dc.description.abstractThis thesis presents two gobal damage detection methods using modal flexibility obtained from ambient acceleration measurements, and a local damage detection method using impednace measurements under temperature variations. Firstly, a vibration-based damage detection method is proposed based on the modal flexibility matrix from ambient vibration measurements for reliable and practical structural health monitoring. The proposed method has three distinct advantages over the convensional methods: (1) the explicit inverse mapping from the damage-induced deflection to the damage location, (2) no requrement for the curvature calculation weak to noises, and (3) no requirement for the intact FEM model. The proposed method utilizes the modal flexibility matrices to estimate deflections under a positive bending inspection load (PBIL) which has been devised to simplify the damage detection procedure in this study. Then, damage can be localized by using the damage-induced deflection and the explicit inverse mapping from the damge-induced deflection to the damage location.Through a series of numerical and experimental studies on continuous beam systems and steel box-girder bridge models with a single and two spans, it has beenfound that the damage locations can be successfully localized by the proposed method. The damage detection performance was found to be superier than the modal strain energy-based damage index method under measurement noisy conditions. Secondly, a substructural damage detection method which requires acceleration measurements within a substructure, is proposed by extending the basic theory of the modal flexibility-based damage detection method to substructural damage detection problems. Novel concepts of the pseudo-modal flexibility and pseudo-modal deflection are introduced for damage detection on a substructure. It has been also found that the damage locations in the two-span steel box-girder bridge model were successfully localized by the pro...eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectStructural Health Monitoring-
dc.subjectDamage Detection-
dc.subjectModal Flexibility-
dc.subjectImpedance-
dc.subjectTemperature effect-
dc.subject구조건전도감시-
dc.subject손상탐색-
dc.subject모드연성도-
dc.subject임피던스-
dc.subject온도효과-
dc.subjectStructural Health Monitoring-
dc.subjectDamage Detection-
dc.subjectModal Flexibility-
dc.subjectImpedance-
dc.subjectTemperature effect-
dc.subject구조건전도감시-
dc.subject손상탐색-
dc.subject모드연성도-
dc.subject임피던스-
dc.subject온도효과-
dc.titleStructural health monitoring methods for bridges using ambient vibration and impedance measurements-
dc.title.alternative상시진동 및 임피던스 계측을 이용한 교량 구조건전도 모니터링 기술-
dc.typeThesis(Ph.D)-
dc.identifier.CNRN295254/325007 -
dc.description.department한국과학기술원 : 건설및환경공학과, -
dc.identifier.uid020015802-
dc.contributor.localauthorYun, Chung-Bang-
dc.contributor.localauthor윤정방-
Appears in Collection
CE-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0