Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

Cited 5 time in webofscience Cited 0 time in scopus
  • Hit : 65
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorGarrett, Londrea J. J.ko
dc.contributor.authorMorgan, Bryan W. W.ko
dc.contributor.authorBurger, Milosko
dc.contributor.authorLee, Yunuko
dc.contributor.authorKim, Hyeongbinko
dc.contributor.authorSabharwall, Piyushko
dc.contributor.authorChoi, Sungyeolko
dc.contributor.authorJovanovic, Igorko
dc.date.accessioned2023-02-13T06:00:45Z-
dc.date.available2023-02-13T06:00:45Z-
dc.date.created2023-02-13-
dc.date.issued2023-01-
dc.identifier.citationSENSORS, v.23, no.2-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/10203/305150-
dc.description.abstractIncreased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma-and neutron-irradiated low OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3 sigma detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 x 10(17) n/cm(2) neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 +/- 610 K to 6900 +/- 810 K and from 15,800 +/- 400 K to 7200 +/- 800 K, respectively, for exposure to the 1.7 x 10(17) n/cm(2) fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.-
dc.languageEnglish-
dc.publisherMDPI-
dc.titleImpact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis-
dc.typeArticle-
dc.identifier.wosid000918775600001-
dc.identifier.scopusid2-s2.0-85146673833-
dc.type.rimsART-
dc.citation.volume23-
dc.citation.issue2-
dc.citation.publicationnameSENSORS-
dc.identifier.doi10.3390/s23020691-
dc.contributor.nonIdAuthorGarrett, Londrea J. J.-
dc.contributor.nonIdAuthorMorgan, Bryan W. W.-
dc.contributor.nonIdAuthorBurger, Milos-
dc.contributor.nonIdAuthorKim, Hyeongbin-
dc.contributor.nonIdAuthorSabharwall, Piyush-
dc.contributor.nonIdAuthorChoi, Sungyeol-
dc.contributor.nonIdAuthorJovanovic, Igor-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorlaser-induced breakdown spectroscopy (LIBS)-
dc.subject.keywordAuthorgamma irradiation-
dc.subject.keywordAuthorneutron irradiation-
dc.subject.keywordAuthoradvanced reactors-
dc.subject.keywordAuthoroptical absorption-
dc.subject.keywordPlusEXPERIMENTAL STARK WIDTHS-
dc.subject.keywordPlusSPECTRAL-LINES-
dc.subject.keywordPlusINDUCED PLASMAS-
dc.subject.keywordPlusLIBS-
dc.subject.keywordPlusSHIFTS-
dc.subject.keywordPlusATOMS-
Appears in Collection
RIMS Journal Papers
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 5 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0