Optimization for size separation of graphene oxide sheets by flow/hyperlayer field-flow fractionation

Cited 1 time in webofscience Cited 0 time in scopus
  • Hit : 137
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKo, Myoungjaeko
dc.contributor.authorChoi, Hee Jaeko
dc.contributor.authorKim, Jin Yongko
dc.contributor.authorKim, In Hoko
dc.contributor.authorKim, Sang Oukko
dc.contributor.authorMoon, Myeong Heeko
dc.date.accessioned2022-10-10T03:01:22Z-
dc.date.available2022-10-10T03:01:22Z-
dc.date.created2022-10-10-
dc.date.created2022-10-10-
dc.date.issued2022-10-
dc.identifier.citationJOURNAL OF CHROMATOGRAPHY A, v.1681-
dc.identifier.issn0021-9673-
dc.identifier.urihttp://hdl.handle.net/10203/298909-
dc.description.abstractGraphene oxide (GO)-a chemical derivative of graphene with numerous oxygen functional groups on its surface-has attracted considerable interest because of its intriguing properties in relation to those of pristine graphene. In addition to the inherent wide lateral size distribution of GO sheets arising from the typical oxidative exfoliation of graphite, control of the lateral size of GO is critical for desired GO-based applications. Herein, flow/hyperlayer field-flow fractionation (flow/hyperlayer FFF) is optimized to sepa-rate GO sheets by lateral dimensions. Optimized fractionation is achieved by investigating the influences of carrier solvent, channel thickness, and flow rate conditions on the steric/hyperlayer separation of GO sheets by flow FFF. Due to the strong hydrodynamic lift forces of extremely thin GO sheets, a thick flow FFF channel ( w = 350 mu m) and a very low field strength are required to retain the GO sheets within the channel. GO sheets with narrow size fractions are successfully collected from two different graphite sources during flow/hyperlayer FFF runs and are examined to verify the size evolution. Considering the average lateral diameter of the GO fraction calculated on the basis of the assumption of a circular disk shape, the retention of the GO sheets is 2.2-5.0 times faster than that of spherical particles of the same diameter. This study demonstrates that through flow/hyperlayer FFF, the size distribution of GO sheets can be determined and narrow size fractions can be collected (which is desirable for GO-based applications), which are commonly influenced by the GO lateral dimension. (c) 2022 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER-
dc.titleOptimization for size separation of graphene oxide sheets by flow/hyperlayer field-flow fractionation-
dc.typeArticle-
dc.identifier.wosid000860956600004-
dc.identifier.scopusid2-s2.0-85137264315-
dc.type.rimsART-
dc.citation.volume1681-
dc.citation.publicationnameJOURNAL OF CHROMATOGRAPHY A-
dc.identifier.doi10.1016/j.chroma.2022.463475-
dc.contributor.localauthorKim, Sang Ouk-
dc.contributor.nonIdAuthorKo, Myoungjae-
dc.contributor.nonIdAuthorKim, Jin Yong-
dc.contributor.nonIdAuthorMoon, Myeong Hee-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorGraphene oxide-
dc.subject.keywordAuthorGO sheets-
dc.subject.keywordAuthorFlow/hyperlayer field-flow fractionation-
dc.subject.keywordAuthorSize size separation of GO-
dc.subject.keywordPlusLIQUID-CRYSTALS-
dc.subject.keywordPlusGRAPHITE-
dc.subject.keywordPlusLAYER-
Appears in Collection
MS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0