Uncooled thermal infrared (IR) camera typically exhibits large DC offset variations and responsivity variations from pixel to pixel. Not only for these variations but PVT (Process, Voltage and Temperature) drift for time cause the undesired output. In order to get a scene information properly, non-uniformity and fixed pattern noise (FPN) from PVT drift must be corrected with reference temperature source such as blackbody. However, the calibration process is not only time-consuming and costly but also must be implemented periodically. To solve the PVT drift, especially, thermal infrared camera typically needs auxiliary component such as TEC (Thermo-Electric Cooler) and shutter during online operation but these additional components cause SWNPC (Size, Weight, Noise, Power, Cost) problems and discontinuity of the image during shutter actuation. This paper proposes novel approaches to overcome the time-consuming and costly calibration without additional components such as TEC and shutter with three ideas; MDCDS (Multi Digital Correlated Double Sampling), Pixel-synchronized temperature sensor and calibration algorithm using chamber wall. This paper includes four-type of the shutter-less algorithms as the number of blackbodies and calibration methods, compared with conventional shutter-based calibration. From this comparison, this research has come to the conclusion that proposed shutter-less algorithms have a better performance for memory, time, cost and RNU, even similar with blackbody calibration, ideal calibration method, which exhibits only random noise of the pixels.
Advisors
Lee, Kwyroresearcher이귀로researcher공동지도교수 영문명researcher공동지도교수 한글명researcher
Description
한국과학기술원 :전기및전자공학부,
Publisher
한국과학기술원
Issue Date
2016
Identifier
325007
Language
eng
Description

학위논문(석사) - 한국과학기술원 : 전기및전자공학부, 2016.8,[vi, 55 p. :]

Keywords

Uncooled thermal infrared camera▼aMicrobolometer▼aFixed Pattern Noise▼aNon-Uniformity Correction▼aResidual Non-Uniformity▼aTEC-less▼aShutter-less; 비냉각형 열영상 카메라▼a마이크로볼로미터▼a고정패턴잡음▼a불균일보정▼a잔여불균일▼a열전냉각기제거▼a셔터제거

URI
http://hdl.handle.net/10203/296032
Link
http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=986329&flag=dissertation
Appears in Collection
EE-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0