Assessment of thermal fatigue induced by dryout front oscillation in printed circuit steam generator

Cited 4 time in webofscience Cited 0 time in scopus
  • Hit : 211
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKwon, Jin Suko
dc.contributor.authorKim, Dohhyeonko
dc.contributor.authorShin, Sung Gilko
dc.contributor.authorLee, Jeong Ikko
dc.contributor.authorKim, Sang Jiko
dc.date.accessioned2022-04-14T06:49:17Z-
dc.date.available2022-04-14T06:49:17Z-
dc.date.created2022-01-06-
dc.date.created2022-01-06-
dc.date.created2022-01-06-
dc.date.created2022-01-06-
dc.date.issued2022-03-
dc.identifier.citationNUCLEAR ENGINEERING AND TECHNOLOGY, v.54, no.3, pp.1085 - 1097-
dc.identifier.issn1738-5733-
dc.identifier.urihttp://hdl.handle.net/10203/292798-
dc.description.abstractA printed circuit steam generator (PCSG) is being considered as the component for pressurized water reactor (PWR) type small modular reactor (SMR) that can further reduce the physical size of the system. Since a steam generator in many PWR-type SMR generates superheated steam, it is expected that dryout front oscillation can potentially cause thermal fatigue failure due to cyclic thermal stresses induced by the transition in boiling regimes between convective evaporation and film boiling. To investigate the fatigue issue of a PCSG, a reference PCSG is designed in this study first using an in-house PCSG design tool. For the stress analysis, a finite element method analysis model is developed to obtain the temperature and stress fields of the designed PCSG. Fatigue estimation is performed based on ASME Boiler and pressure vessel code to identify the major parameters influencing the fatigue life time originating from the dryout front oscillation. As a result of this study, the limit on the temperature difference between the hot side and cold side fluids is obtained. Moreover, it is found that the heat transfer coefficient of convective evaporation and film boiling regimes play an essential role in the fatigue life cycle as well as the temperature difference.-
dc.languageEnglish-
dc.publisherKOREAN NUCLEAR SOC-
dc.titleAssessment of thermal fatigue induced by dryout front oscillation in printed circuit steam generator-
dc.typeArticle-
dc.identifier.wosid000766667500015-
dc.identifier.scopusid2-s2.0-85114807989-
dc.type.rimsART-
dc.citation.volume54-
dc.citation.issue3-
dc.citation.beginningpage1085-
dc.citation.endingpage1097-
dc.citation.publicationnameNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.identifier.doi10.1016/j.net.2021.09.004-
dc.identifier.kciidART002813490-
dc.contributor.localauthorLee, Jeong Ik-
dc.contributor.nonIdAuthorKim, Sang Ji-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorPCSGThermal fatigueDryout oscillationFEM-
dc.subject.keywordPlusCOOLED FAST-REACTORHEAT-TRANSFERDESIGNCO2-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0