Re-mobilization of Lost Coronary Stent From the Axillary Artery to the Femoral Artery

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 146
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, Jeong Seokko
dc.contributor.authorKim, HLko
dc.contributor.authorSeo, JBko
dc.contributor.authorLim, WHko
dc.contributor.authorKang, EGko
dc.contributor.authorChung, WYko
dc.contributor.authorKim, SHko
dc.contributor.authorJo, ZHko
dc.contributor.authorKim, MAko
dc.date.accessioned2022-01-06T06:41:09Z-
dc.date.available2022-01-06T06:41:09Z-
dc.date.created2022-01-06-
dc.date.created2022-01-06-
dc.date.issued2016-06-
dc.identifier.citationJournal of Lipid and Atherosclerosis, v.5, no.1, pp.87 - 92-
dc.identifier.issn2287-2892-
dc.identifier.urihttp://hdl.handle.net/10203/291626-
dc.description.abstractStent migration and loss are rare but can be devastating complications during percutaneous coronary intervention (PCI) for coronary artery disease. We report a unique case of wandering stent from the right coronary artery to the femoral artery via the axillary artery. Initially, the stent was stripped from the delivery catheter and embolized to axillary artery during emergent PCI. An intra-aortic balloon pump might have forced retrograde movement of the stent to axillary artery which have subsequently remobilized to the femoral artery. After stabilization, the stent was successfully removed by a percutaneous approach using a snare. Immediate retrieval of wandering stent is recommended for the prevention of secondary embolization.-
dc.languageEnglish-
dc.publisherThe Korean Society of Lipidology and Atherosclerosis-
dc.titleRe-mobilization of Lost Coronary Stent From the Axillary Artery to the Femoral Artery-
dc.typeArticle-
dc.type.rimsART-
dc.citation.volume5-
dc.citation.issue1-
dc.citation.beginningpage87-
dc.citation.endingpage92-
dc.citation.publicationnameJournal of Lipid and Atherosclerosis-
dc.identifier.doi10.12997/jla.2016.5.1.87-
dc.contributor.localauthorLee, Jeong Seok-
dc.contributor.nonIdAuthorKim, HL-
dc.contributor.nonIdAuthorSeo, JB-
dc.contributor.nonIdAuthorLim, WH-
dc.contributor.nonIdAuthorKang, EG-
dc.contributor.nonIdAuthorChung, WY-
dc.contributor.nonIdAuthorKim, SH-
dc.contributor.nonIdAuthorJo, ZH-
dc.contributor.nonIdAuthorKim, MA-
dc.description.isOpenAccessN-
Appears in Collection
MSE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0