A Precise Lesion Localization System Using a Magnetometer With Real-Time Baseline Cancellation for Laparoscopic Surgery

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 170
  • Download : 123
DC FieldValueLanguage
dc.contributor.authorKweon, Soon-Jaeko
dc.contributor.authorYun, Woojinko
dc.contributor.authorPark, Hyunwooko
dc.contributor.authorPark, Jeong-Hoko
dc.contributor.authorLee, Jung Hoonko
dc.contributor.authorLee, Jinko
dc.contributor.authorJe, Minkyuko
dc.contributor.authorHa, Sohmyungko
dc.contributor.authorKim, Choul-Youngko
dc.date.accessioned2021-10-11T04:51:02Z-
dc.date.available2021-10-11T04:51:02Z-
dc.date.created2021-10-11-
dc.date.created2021-10-11-
dc.date.created2021-10-11-
dc.date.issued2021-
dc.identifier.citationIEEE ACCESS, v.9, pp.131648 - 131657-
dc.identifier.issn2169-3536-
dc.identifier.urihttp://hdl.handle.net/10203/288128-
dc.description.abstractLaparoscopic surgery is a technique in which surgeons insert laparoscopic instruments into the body through a small incision and conduct surgical operations. It offers a shorter recovery period, less blood loss, and less postoperative pain than open surgeries. In order to maximize these benefits of this surgery technique, it is important to localize the lesion accurately without palpation, minimizing the surgical area. It is because surgeons cannot palpate the organ during laparoscopic surgeries. For accurate localization, we propose a lesion localization system (LLS). This adopts an endoscopic clip with a small-size magnet as a marker and an improved magnetometer as a probe for measuring the magnetic field from the magnet. The magnetometer, which consists of two Hall sensors, can cancel out the fluctuating magnetic baseline mainly caused by external environments so that it can detect a smaller change in the target magnetic field. As a result, the LLS improves the detection range up to 40 mm while using a weak magnet with a small volume of 17.1 mm(3), which is compatible with the use of commercial clip appliers. An error of less than 0.1% is achieved at a distance of 40 mm, and the maximum error is kept below 6% even when the rotation angle is varied to +/- 90 degrees. This LLS does not cause discomfort to the surgery operation because it uses a marker small enough and does not require external coils.-
dc.languageEnglish-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titleA Precise Lesion Localization System Using a Magnetometer With Real-Time Baseline Cancellation for Laparoscopic Surgery-
dc.typeArticle-
dc.identifier.wosid000701215000001-
dc.identifier.scopusid2-s2.0-85115149652-
dc.type.rimsART-
dc.citation.volume9-
dc.citation.beginningpage131648-
dc.citation.endingpage131657-
dc.citation.publicationnameIEEE ACCESS-
dc.identifier.doi10.1109/ACCESS.2021.3113566-
dc.contributor.localauthorJe, Minkyu-
dc.contributor.nonIdAuthorYun, Woojin-
dc.contributor.nonIdAuthorLee, Jung Hoon-
dc.contributor.nonIdAuthorLee, Jin-
dc.contributor.nonIdAuthorHa, Sohmyung-
dc.contributor.nonIdAuthorKim, Choul-Young-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorMagnetometers-
dc.subject.keywordAuthorLesions-
dc.subject.keywordAuthorMinimally invasive surgery-
dc.subject.keywordAuthorAntennas-
dc.subject.keywordAuthorInk-
dc.subject.keywordAuthorEndoscopes-
dc.subject.keywordAuthorLight emitting diodes-
dc.subject.keywordAuthorBaseline cancellation-
dc.subject.keywordAuthorendoscopic clip-
dc.subject.keywordAuthorhall sensor-
dc.subject.keywordAuthorlaparoscopic surgery-
dc.subject.keywordAuthorlesion localization-
dc.subject.keywordAuthormagnetometer-
dc.subject.keywordAuthorminimally invasive surgery-
dc.subject.keywordAuthorprecision-
dc.subject.keywordAuthorsmall-sized magnet-
dc.subject.keywordPlusASSISTED DISTAL GASTRECTOMY-
dc.subject.keywordPlusGASTRIC-CANCER-
dc.subject.keywordPlusINDIA INK-
dc.subject.keywordPlusMARKING-
dc.subject.keywordPlusFUSION-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
121927.pdf(1.7 MB)Download

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0