Development of a filtered AXUV diode array for X-pinch soft x-ray spectra in the energy range of 1-10 keV

Cited 4 time in webofscience Cited 0 time in scopus
  • Hit : 268
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorHam, Seunggiko
dc.contributor.authorRyu, Jonghyeonko
dc.contributor.authorPark, Sungbinko
dc.contributor.authorChung, Kyoung-Jaeko
dc.contributor.authorGhim, Young-chulko
dc.contributor.authorWoo, H. J.ko
dc.contributor.authorHwang, Y. S.ko
dc.date.accessioned2021-09-14T04:50:30Z-
dc.date.available2021-09-14T04:50:30Z-
dc.date.created2021-09-14-
dc.date.created2021-09-14-
dc.date.issued2021-05-
dc.identifier.citationREVIEW OF SCIENTIFIC INSTRUMENTS, v.92, no.5-
dc.identifier.issn0034-6748-
dc.identifier.urihttp://hdl.handle.net/10203/287755-
dc.description.abstractWe develop a filtered absolute extreme ultraviolet (AXUV) diode array to measure the time evolution of the soft x-ray spectrum in the energy range of 1-10 keV. AXUV-HS5, the detector, has a fast rise time of 0.7 ns, a wide energy detection range, and high accessibility. We use Geant4 simulations to design an appropriate filter set for flat-and-sharp virtual channels (VCs), where a filter with no spectral edge removes large tails of the response curves. A Levenberg-Marquardt (LM) method, sensitive to the expected spectral function, is improved to reliably generate a continuous radiation spectrum, by utilizing spectral information from the least-squares (LS) method that reconstructs a discrete spectrum with low spectral resolution directly from the VCs. We test the filtered AXUV diode array on an X-pinch device with a peak current of 140 kA at Seoul National University; the array with ten channels is installed in a vacuum chamber. For a two-wire 40 mu m stainless steel X-pinch, x-ray power, radiation temperature, and the reconstructed x-ray spectrum are obtained from the filtered AXUV diode array by the combined LS-LM method. Published under license by AIP Publishing.-
dc.languageEnglish-
dc.publisherAIP Publishing-
dc.titleDevelopment of a filtered AXUV diode array for X-pinch soft x-ray spectra in the energy range of 1-10 keV-
dc.typeArticle-
dc.identifier.wosid000691996700004-
dc.identifier.scopusid2-s2.0-85105502456-
dc.type.rimsART-
dc.citation.volume92-
dc.citation.issue5-
dc.citation.publicationnameREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.identifier.doi10.1063/5.0034638-
dc.contributor.localauthorGhim, Young-chul-
dc.contributor.nonIdAuthorHam, Seunggi-
dc.contributor.nonIdAuthorRyu, Jonghyeon-
dc.contributor.nonIdAuthorPark, Sungbin-
dc.contributor.nonIdAuthorChung, Kyoung-Jae-
dc.contributor.nonIdAuthorWoo, H. J.-
dc.contributor.nonIdAuthorHwang, Y. S.-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordPlusEMISSION-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0