Silicon nanopillar-based open microfluidic channel integrated biosensor for real-time detection실시간 검출을 위한 나노 기둥기반 개방형 미세 유체 채널 일체형 CMUT 바이오센서

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 152
  • Download : 0
This thesis reports the silicon nanopillar-based open channel system for real-time detection. Capacitive micromachined ultrasonic transducer (CMUT) is a MEMS-based device that has high quality factor due to its vacuum cavity. Therefore, it has potential as sensitive micro-biosensor. However, in water condition, the sensitivity of CMUT is decreased by damping. By this reason, it is difficult that conventional microfluidic channel system is applied to CMUT sensor for real-time monitoring. Here, we suggest a silicon nanopillar-based open channel system using wicking flow for real-time detection. The effect of nanopillar structure was confirmed by FEM simulation. In addition, the pillar structure was fabricated. Thus, we demonstrate the potential of the open channel system as real-time monitoring system.
Advisors
Lee, Hyunjoo Jennyresearcher이현주researcher
Description
한국과학기술원 :전기및전자공학부,
Publisher
한국과학기술원
Issue Date
2019
Identifier
325007
Language
eng
Description

학위논문(석사) - 한국과학기술원 : 전기및전자공학부, 2019.8,[iii, 32 p. :]

Keywords

Capillary flow▼amicrofluidic channel▼aCMUT▼aMEMS; 모세관 현상▼a미세 유체 채널▼a미세가공 정전용량형 초음파 트랜스듀서(CMUT)▼aMEMS