Improvement of work function and hole injection efficiency of graphene anode using CHF3 plasma treatment

Cited 18 time in webofscience Cited 11 time in scopus
  • Hit : 128
  • Download : 0
We report improvement of hole injection efficiency of a graphene anode by tuning its work function (WF) via surface fluorination. We used chemical vapor deposition to synthesize high-quality graphene sheets and then treated them with CHF3 plasma to induce fluorination. We used x-ray photoelectron spectroscopy to examine the fluorine coverage and the kind of chemical bonds in fluorinated graphene (FG). Also, we used ultraviolet photoelectron spectroscopy to systematically study the changes in the WF and sheet resistance of the FG sheets with varying plasma exposure time (0, 10, 30, 60, 90 s) to find an optimum fluorination condition for hole injection. The WF of graphene sheets was increased by up to 0.74 eV, as a result of the formation of carbon-fluorine bonds that function as negative surface dipoles. We fabricated hole-only devices and conducted dark injection space-charge-limited-current transient measurement; the fluorination greatly increased the hole injection efficiency of graphene anodes (from 0.237 to 0.652). The enhanced hole injection efficiency of FG anodes in our study provides wide opportunities for applications in graphene-based flexible/stretchable organic optoelectronics.
Publisher
IOP PUBLISHING LTD
Issue Date
2015-03
Language
English
Article Type
Article
Citation

2D MATERIALS, v.2, no.1

ISSN
2053-1583
DOI
10.1088/2053-1583/2/1/014002
URI
http://hdl.handle.net/10203/281277
Appears in Collection
MS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 18 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0