Wireless, implantable catheter-type oximeter designed for cardiac oxygen saturation

Cited 46 time in webofscience Cited 16 time in scopus
  • Hit : 405
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLu, Weiko
dc.contributor.authorBai, Wubinko
dc.contributor.authorZhang, Haoko
dc.contributor.authorXu, Chenkaiko
dc.contributor.authorChiarelli, Antonio M.ko
dc.contributor.authorVázquez-Guardado, Abrahamko
dc.contributor.authorXie, Zhaoqianko
dc.contributor.authorShen, Haixuko
dc.contributor.authorNandoliya, Khizarko
dc.contributor.authorZhao, Hangboko
dc.contributor.authorLee, KunHyuckko
dc.contributor.authorWu, Yixinko
dc.contributor.authorFranklin, Danielko
dc.contributor.authorAvila, Raudelko
dc.contributor.authorXu, Shuaiko
dc.contributor.authorRwei, Alinako
dc.contributor.authorHan, Mengdiko
dc.contributor.authorKwon, Kyeonghako
dc.contributor.authorDeng, Yujunko
dc.contributor.authorYu, Xingeko
dc.contributor.authorThorp, Edward B.ko
dc.contributor.authorFeng, Xueko
dc.contributor.authorHuang, Yonggangko
dc.contributor.authorForbess, Josephko
dc.contributor.authorGe, Zhi-Dongko
dc.contributor.authorRogers, John A.ko
dc.date.accessioned2021-02-19T00:50:11Z-
dc.date.available2021-02-19T00:50:11Z-
dc.date.created2021-02-17-
dc.date.created2021-02-17-
dc.date.created2021-02-17-
dc.date.issued2021-02-
dc.identifier.citationSCIENCE ADVANCES, v.7, no.7, pp.eabe0579-
dc.identifier.issn2375-2548-
dc.identifier.urihttp://hdl.handle.net/10203/280874-
dc.description.abstractAccurate, real-time monitoring of intravascular oxygen levels is important in tracking the cardiopulmonary health of patients after cardiothoracic surgery. Existing technologies use intravascular placement of glass fiber-optic catheters that pose risks of blood vessel damage, thrombosis, and infection. In addition, physical tethers to power supply systems and data acquisition hardware limit freedom of movement and add clutter to the intensive care unit. This report introduces a wireless, miniaturized, implantable optoelectronic catheter system incorporating optical components on the probe, encapsulated by soft biocompatible materials, as alternative technology that avoids these disadvantages. The absence of physical tethers and the flexible, biocompatible construction of the probe represent key defining features, resulting in a high-performance, patient-friendly implantable oximeter that can monitor localized tissue oxygenation, heart rate, and respiratory activity with wireless, real-time, continuous operation. In vitro and in vivo testing shows that this platform offers measurement accuracy and precision equivalent to those of existing clinical standards.-
dc.languageEnglish-
dc.publisherAMER ASSOC ADVANCEMENT SCIENCE-
dc.titleWireless, implantable catheter-type oximeter designed for cardiac oxygen saturation-
dc.typeArticle-
dc.identifier.wosid000617708700021-
dc.identifier.scopusid2-s2.0-85100953499-
dc.type.rimsART-
dc.citation.volume7-
dc.citation.issue7-
dc.citation.beginningpageeabe0579-
dc.citation.publicationnameSCIENCE ADVANCES-
dc.identifier.doi10.1126/sciadv.abe0579-
dc.contributor.localauthorKwon, Kyeongha-
dc.contributor.nonIdAuthorLu, Wei-
dc.contributor.nonIdAuthorBai, Wubin-
dc.contributor.nonIdAuthorZhang, Hao-
dc.contributor.nonIdAuthorXu, Chenkai-
dc.contributor.nonIdAuthorChiarelli, Antonio M.-
dc.contributor.nonIdAuthorVázquez-Guardado, Abraham-
dc.contributor.nonIdAuthorXie, Zhaoqian-
dc.contributor.nonIdAuthorShen, Haixu-
dc.contributor.nonIdAuthorNandoliya, Khizar-
dc.contributor.nonIdAuthorZhao, Hangbo-
dc.contributor.nonIdAuthorLee, KunHyuck-
dc.contributor.nonIdAuthorWu, Yixin-
dc.contributor.nonIdAuthorFranklin, Daniel-
dc.contributor.nonIdAuthorAvila, Raudel-
dc.contributor.nonIdAuthorXu, Shuai-
dc.contributor.nonIdAuthorRwei, Alina-
dc.contributor.nonIdAuthorHan, Mengdi-
dc.contributor.nonIdAuthorDeng, Yujun-
dc.contributor.nonIdAuthorYu, Xinge-
dc.contributor.nonIdAuthorThorp, Edward B.-
dc.contributor.nonIdAuthorFeng, Xue-
dc.contributor.nonIdAuthorHuang, Yonggang-
dc.contributor.nonIdAuthorForbess, Joseph-
dc.contributor.nonIdAuthorGe, Zhi-Dong-
dc.contributor.nonIdAuthorRogers, John A.-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 46 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0