Ductile fracture predictions in small punch testing of cold-rolled aluminium alloy

Cited 13 time in webofscience Cited 11 time in scopus
  • Hit : 318
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorSebek, Frantisekko
dc.contributor.authorPark, Namsuko
dc.contributor.authorKubik, Petrko
dc.contributor.authorPetruska, Jindrichko
dc.contributor.authorZapletal, Josefko
dc.date.accessioned2019-01-23T06:53:25Z-
dc.date.available2019-01-23T06:53:25Z-
dc.date.created2019-01-14-
dc.date.issued2019-02-
dc.identifier.citationENGINEERING FRACTURE MECHANICS, v.206, pp.509 - 525-
dc.identifier.issn0013-7944-
dc.identifier.urihttp://hdl.handle.net/10203/250090-
dc.description.abstractThe ductile fracture has been observed in large as well as small scales. Three chosen Lode and pressure dependent phenomenological ductile fracture criteria with cut-offs were calibrated for aluminium alloy EN AW 2024-T351 using an enhanced hybrid experimental-numerical technique. It consisted of calibrating all the material constants of fracture criteria altogether. This enabled ready determination of the cut-off related constant for one of those criteria. Moreover, a non-quadratic Lode dependent plasticity model was coupled with the ductile failure criteria to form the damage plasticity approach in the numerical analysis. The fracture criteria were calibrated using the standard - large - sized specimens including a non-standard upsetting test. The specimens used for the calibration of failure criteria are usually ten times larger than that of a specimen for the small punch test. The transferability of calibrated parameters was tested and fair predictability was observed for all numerical models when applied to small scales.-
dc.languageEnglish-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleDuctile fracture predictions in small punch testing of cold-rolled aluminium alloy-
dc.typeArticle-
dc.identifier.wosid000454511700032-
dc.identifier.scopusid2-s2.0-85057435564-
dc.type.rimsART-
dc.citation.volume206-
dc.citation.beginningpage509-
dc.citation.endingpage525-
dc.citation.publicationnameENGINEERING FRACTURE MECHANICS-
dc.identifier.doi10.1016/j.engfracmech.2018.11.045-
dc.contributor.nonIdAuthorSebek, Frantisek-
dc.contributor.nonIdAuthorKubik, Petr-
dc.contributor.nonIdAuthorPetruska, Jindrich-
dc.contributor.nonIdAuthorZapletal, Josef-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
Appears in Collection
RIMS Journal Papers
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 13 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0