Highly sensitive Mach-Zehnder interferometer biosensor based on silicon nitride slot waveguide

Cited 182 time in webofscience Cited 0 time in scopus
  • Hit : 198
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLiu, Qingko
dc.contributor.authorTu, Xiaoguangko
dc.contributor.authorKim, Kyung Wooko
dc.contributor.authorKee, Jack Shengko
dc.contributor.authorShin, Yongko
dc.contributor.authorHan, Kyungsupko
dc.contributor.authorYoon, Yong-Jinko
dc.contributor.authorLo, Guo-Qiangko
dc.contributor.authorPark, Mi Kyoungko
dc.date.accessioned2018-10-19T00:35:58Z-
dc.date.available2018-10-19T00:35:58Z-
dc.date.created2018-09-10-
dc.date.created2018-09-10-
dc.date.created2018-09-10-
dc.date.issued2013-11-
dc.identifier.citationSENSORS AND ACTUATORS B-CHEMICAL, v.188, pp.681 - 688-
dc.identifier.issn0925-4005-
dc.identifier.urihttp://hdl.handle.net/10203/245984-
dc.description.abstractWe demonstrate a highly sensitive label-free Mach-Zehnder interferometer (MZI) biosensor based on silicon nitride slot waveguide. Unlike the conventional MZI sensors, the sensing arm of the sensor consists of a slot waveguide while the reference arm consists of a strip waveguide. Thanks to the slot waveguide's property to provide high optical intensity in a subwavelength-size low refractive index region (slot region), which allows high light-analyte interaction, higher sensitivity can be obtained as compared to conventional waveguides using the slot waveguide as sensing region. The bulk refractive index sensitivity of the slot waveguide MZI sensor was found to be 1864 pi/RIU (refractive index unit) with 7 mm long slot waveguide sensing arm, which shows higher sensitivity compared to the conventional MZI device based on silicon nitride. The biosensing capability of the developed slot waveguide MZI was investigated using biotin-streptavidin binding as a model system. The sensitivity of the system was demonstrated down to 18.9 fM or 1 pg/ml of streptavidin solution and to the best of our knowledge, it is the best reported experimental value for the limit of detection of a MZI sensor. Furthermore, we investigated the specific detection and quantification of the methylation of DAPIC (Death-associated protein kinase) gene, which is a widely used biomarker for human cancers. We have shown that methylation sequences of DAPIC gene of various methylation densities (100%, 50%, and 0% of methylation sites) can be quantified and discriminated even at a concentration as low as 1 fmol/mu l or 1 nM. (C) 2013 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE SA-
dc.subjectPHOTONIC MICRORING RESONATORS-
dc.subjectLABEL-FREE-
dc.subjectMULTIPLEXED DETECTION-
dc.subjectON-INSULATOR-
dc.subjectDAP-KINASE-
dc.subjectSENSOR-
dc.subjectCANCER-
dc.subjectARRAYS-
dc.subjectHYPERMETHYLATION-
dc.subjectRECOGNITION-
dc.titleHighly sensitive Mach-Zehnder interferometer biosensor based on silicon nitride slot waveguide-
dc.typeArticle-
dc.identifier.wosid000326345600092-
dc.identifier.scopusid2-s2.0-84883088780-
dc.type.rimsART-
dc.citation.volume188-
dc.citation.beginningpage681-
dc.citation.endingpage688-
dc.citation.publicationnameSENSORS AND ACTUATORS B-CHEMICAL-
dc.identifier.doi10.1016/j.snb.2013.07.053-
dc.contributor.localauthorYoon, Yong-Jin-
dc.contributor.nonIdAuthorLiu, Qing-
dc.contributor.nonIdAuthorTu, Xiaoguang-
dc.contributor.nonIdAuthorKim, Kyung Woo-
dc.contributor.nonIdAuthorKee, Jack Sheng-
dc.contributor.nonIdAuthorShin, Yong-
dc.contributor.nonIdAuthorHan, Kyungsup-
dc.contributor.nonIdAuthorLo, Guo-Qiang-
dc.contributor.nonIdAuthorPark, Mi Kyoung-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorMach-Zehnder interferometer-
dc.subject.keywordAuthorSilicon nitride waveguide-
dc.subject.keywordAuthorSlot waveguide-
dc.subject.keywordAuthorLabel free detection-
dc.subject.keywordAuthorOptical biosensor-
dc.subject.keywordAuthorMach-Zehnder interferometer-
dc.subject.keywordAuthorSilicon nitride waveguide-
dc.subject.keywordAuthorSlot waveguide-
dc.subject.keywordAuthorLabel free detection-
dc.subject.keywordAuthorOptical biosensor-
dc.subject.keywordPlusPHOTONIC MICRORING RESONATORS-
dc.subject.keywordPlusLABEL-FREE-
dc.subject.keywordPlusMULTIPLEXED DETECTION-
dc.subject.keywordPlusON-INSULATOR-
dc.subject.keywordPlusDAP-KINASE-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusARRAYS-
dc.subject.keywordPlusHYPERMETHYLATION-
dc.subject.keywordPlusRECOGNITION-
dc.subject.keywordPlusPHOTONIC MICRORING RESONATORS-
dc.subject.keywordPlusLABEL-FREE-
dc.subject.keywordPlusMULTIPLEXED DETECTION-
dc.subject.keywordPlusON-INSULATOR-
dc.subject.keywordPlusDAP-KINASE-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusCANCER-
dc.subject.keywordPlusARRAYS-
dc.subject.keywordPlusHYPERMETHYLATION-
dc.subject.keywordPlusRECOGNITION-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 182 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0