Note: Precision viscosity measurement using suspended microchannel resonators

Cited 34 time in webofscience Cited 0 time in scopus
  • Hit : 138
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, I.ko
dc.contributor.authorPark, K.ko
dc.contributor.authorLee, Jungchulko
dc.date.accessioned2018-09-18T05:54:17Z-
dc.date.available2018-09-18T05:54:17Z-
dc.date.created2018-08-21-
dc.date.created2018-08-21-
dc.date.issued2012-11-
dc.identifier.citationREVIEW OF SCIENTIFIC INSTRUMENTS, v.83, no.11-
dc.identifier.issn0034-6748-
dc.identifier.urihttp://hdl.handle.net/10203/245474-
dc.description.abstractWe report the characterization of a suspended microchannel resonator (SMR) for viscosity measurements in a low viscosity regime (<10 mPa s) using two measurement schemes. First, the quality factor (Q-factor) of the SMR was characterized with glycerol-water mixtures. The measured Q-factor at 20 degrees C exhibits a bilinear behavior with the sensitivity of 1281 (mPa s)(-1) for a lower (1-4 mPa s) and 355 (mPa s)-1 for a higher viscosity range (4-8 mPa s), respectively. The second scheme is the vibration amplitude monitoring of the SMR running in a closed loop feedback. When compared in terms of the measurement time, the amplitude-based measurement takes only 0.1 similar to 1 ms while the Q-factor-based measurement takes similar to 30 s. However, the viscosity resolution of the Q-factor-based measurement is at least three times better than the amplitude-based measurement. By comparing the Q-factors of heavy water and 9.65 wt.% glycerol-water mixture that have very similar viscosities but different densities, we confirmed that the SMR can measure the dynamic viscosity without the density correction. The obtained results demonstrate that the SMR can measure the fluid viscosity with high precision and even real-time monitoring of the viscosity change is possible with the amplitude-based measurement scheme. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4768245]-
dc.languageEnglish-
dc.publisherAMER INST PHYSICS-
dc.subjectCAPILLARY VISCOMETER-
dc.subjectLIQUIDS-
dc.subjectFLUID-
dc.titleNote: Precision viscosity measurement using suspended microchannel resonators-
dc.typeArticle-
dc.identifier.wosid000312034400070-
dc.identifier.scopusid2-s2.0-84870554799-
dc.type.rimsART-
dc.citation.volume83-
dc.citation.issue11-
dc.citation.publicationnameREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.identifier.doi10.1063/1.4768245-
dc.contributor.localauthorLee, Jungchul-
dc.contributor.nonIdAuthorLee, I.-
dc.contributor.nonIdAuthorPark, K.-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordPlusCAPILLARY VISCOMETER-
dc.subject.keywordPlusLIQUIDS-
dc.subject.keywordPlusFLUID-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 34 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0