DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Gun Rae | ko |
dc.contributor.author | Kim, Seong Tae | ko |
dc.contributor.author | Kim, Jung | ko |
dc.date.accessioned | 2018-06-16T07:37:39Z | - |
dc.date.available | 2018-06-16T07:37:39Z | - |
dc.date.created | 2018-06-11 | - |
dc.date.created | 2018-06-11 | - |
dc.date.created | 2018-06-11 | - |
dc.date.issued | 2018-05 | - |
dc.identifier.citation | INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, v.19, no.5, pp.675 - 684 | - |
dc.identifier.issn | 2234-7593 | - |
dc.identifier.uri | http://hdl.handle.net/10203/242548 | - |
dc.description.abstract | In the paper, a backlash compensator is proposed for accurate position control of the needle manipulator for the magnetic resonance imaging (MRI) guided biopsy. Having long cable driven transmission, the robot guarantees the MR-compatibility, but has accuracy degradation due to the backlash problem. To handle the problem, a backlash compensator is proposed based on the Prandtl-Ishlinskii model, regarding the continuity of the control input. The particle swarm optimization is used to identify the backlash model. Through the experiments, it is verified that the proposed compensator can reduce the tracking error dramatically, and can provide adequate accuracy for the biopsy operation. | - |
dc.language | English | - |
dc.publisher | KOREAN SOC PRECISION ENG | - |
dc.title | Backlash Compensation for Accurate Control of Biopsy Needle Manipulators having Long Cable Transmission | - |
dc.type | Article | - |
dc.identifier.wosid | 000432912000004 | - |
dc.identifier.scopusid | 2-s2.0-85047208932 | - |
dc.type.rims | ART | - |
dc.citation.volume | 19 | - |
dc.citation.issue | 5 | - |
dc.citation.beginningpage | 675 | - |
dc.citation.endingpage | 684 | - |
dc.citation.publicationname | INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING | - |
dc.identifier.doi | 10.1007/s12541-018-0081-4 | - |
dc.contributor.localauthor | Kim, Jung | - |
dc.contributor.nonIdAuthor | Cho, Gun Rae | - |
dc.description.isOpenAccess | N | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | Biopsy needle manipulator | - |
dc.subject.keywordAuthor | Backlash compensation | - |
dc.subject.keywordAuthor | Prandtl-Ishlinskii model | - |
dc.subject.keywordAuthor | Particle swarm optimization | - |
dc.subject.keywordAuthor | MR-compatibility | - |
dc.subject.keywordAuthor | Cable transmission | - |
dc.subject.keywordPlus | MR-COMPATIBLE ROBOTICS | - |
dc.subject.keywordPlus | FUZZY-LOGIC | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordPlus | MODEL | - |
dc.subject.keywordPlus | OPTIMIZATION | - |
dc.subject.keywordPlus | INVERSION | - |
dc.subject.keywordPlus | FEEDBACK | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.