Chemical Degradation of Commercial Polymer Electrolyte Membrane for Vanadium Redox Flow Battery (VRFB)

Cited 3 time in webofscience Cited 0 time in scopus
  • Hit : 612
  • Download : 0
Durability test of commercial polymer electrolyte membranes investigated because longer performance of VRFB depends on the membrane's chemical stability. For hydrolytic stability test, distilled water and membrane was placed in the pressurized container, activated for 24 h at 200 degrees C to check the weight loss, and distilled water's pH change. To confirm the chemical degradation, the membrane was impregnated in 0.1 M V(V) solution for 72 h and concentration change was measured by UV-vis Spectrum. Through this experiment, anion exchange membrane in VRFB is considered in terms of chemical degradation.
Publisher
AMER SCIENTIFIC PUBLISHERS
Issue Date
2017-08
Language
English
Article Type
Article
Keywords

POLY(PHENYLENE OXIDE)

Citation

JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, v.17, no.8, pp.5788 - 5791

ISSN
1533-4880
DOI
10.1166/jnn.2017.14171
URI
http://hdl.handle.net/10203/225128
Appears in Collection
CBE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 3 items in WoS Click to see citing articles in records_button