DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hoyeon | ko |
dc.contributor.author | Min, Jonghwan | ko |
dc.contributor.author | Lee, Taewon | ko |
dc.contributor.author | Dumangeng Pua, Rizza | ko |
dc.contributor.author | Sabir, Sohail | ko |
dc.contributor.author | Yoon, Kown-Ha | ko |
dc.contributor.author | Kim, Hokyung | ko |
dc.contributor.author | Cho, Seungryong | ko |
dc.date.accessioned | 2017-05-15T05:20:16Z | - |
dc.date.available | 2017-05-15T05:20:16Z | - |
dc.date.created | 2017-05-08 | - |
dc.date.created | 2017-05-08 | - |
dc.date.issued | 2017-03 | - |
dc.identifier.citation | IEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.64, no.3, pp.908 - 914 | - |
dc.identifier.issn | 0018-9499 | - |
dc.identifier.uri | http://hdl.handle.net/10203/223705 | - |
dc.description.abstract | Cone-beam computed tomography (CBCT) is gaining widespread use in various medical and industrial applications but suffers from substantially larger amount of scatter than that in the conventional diagnostic CT resulting in relatively poor image quality. Various methods that can reduce and/or correct for the scatter in the CBCT have therefore been developed. Scatter correction method that uses a beam-blocker has been considered a direct measurement-based approach providing accurate scatter estimation from the data in the shadows of the beam-blocker. To the best of our knowledge, there has been no record reporting the significance of the scatter from the beam-blocker itself in such correction methods. In this paper, we identified the scatter from the beam-blocker that is detected in the object-free projection data investigated its influence on the image accuracy of CBCT reconstructed images, and developed a scatter correction scheme that takes care of this scatter as well as the scatter from the scanned object. | - |
dc.language | English | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | X-RAY SCATTER | - |
dc.subject | COMPUTED-TOMOGRAPHY | - |
dc.subject | IMAGE QUALITY | - |
dc.subject | ALGORITHM | - |
dc.subject | REDUCTION | - |
dc.title | Investigation on Beam-Blocker-Based Scatter Correction Method for Improving CT Number Accuracy | - |
dc.type | Article | - |
dc.identifier.wosid | 000399248400003 | - |
dc.identifier.scopusid | 2-s2.0-85017329228 | - |
dc.type.rims | ART | - |
dc.citation.volume | 64 | - |
dc.citation.issue | 3 | - |
dc.citation.beginningpage | 908 | - |
dc.citation.endingpage | 914 | - |
dc.citation.publicationname | IEEE TRANSACTIONS ON NUCLEAR SCIENCE | - |
dc.identifier.doi | 10.1109/TNS.2017.2669519 | - |
dc.contributor.localauthor | Cho, Seungryong | - |
dc.contributor.nonIdAuthor | Yoon, Kown-Ha | - |
dc.contributor.nonIdAuthor | Kim, Hokyung | - |
dc.description.isOpenAccess | N | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | Beam-blocker | - |
dc.subject.keywordAuthor | cone-beam computed tomography (CBCT) | - |
dc.subject.keywordAuthor | scatter correction | - |
dc.subject.keywordPlus | X-RAY SCATTER | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | IMAGE QUALITY | - |
dc.subject.keywordPlus | ALGORITHM | - |
dc.subject.keywordPlus | REDUCTION | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.