Optical inspection of smartphone camera modules by near-infrared low-coherence interferometry

Cited 2 time in webofscience Cited 0 time in scopus
  • Hit : 331
  • Download : 0
High-resolution cameras used for smartphones are comprised of multiple aspheric lenses, a spectral filter, and a semiconductor image sensor, which are packaged together into a single module with tight geometrical tolerances. We investigated the technical possibility of near-infrared low-coherence interferometry for nondestructive geometrical inspection of the complex camera module to examine the inside packaging state. This tomographic scheme enabled us to measure the relative axial position of each inside component and also the lateral surface profile of the image sensor, allowing for comprehensive three-dimensional quality assurance of the whole camera module during the packaging process. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE).
Publisher
SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS
Issue Date
2016-09
Language
English
Article Type
Article
Citation

OPTICAL ENGINEERING, v.55, no.9

ISSN
0091-3286
DOI
10.1117/1.OE.55.9.091404
URI
http://hdl.handle.net/10203/218335